- EN -
SPARE PARTS
The use of original parts from OASE ensures contin-
ued safe and reliable operation of the unit.
Please visit our website for spare parts drawings
and spare parts.
REMEDY OF FAULTS
Malfunction
The water does not heat up. No mains voltage
Water does not reach the
set temperature.
TECHNICAL DATA
Designation
Rated voltage
Power consumption
Regulating range
Dimensions
22
www.oase-livingwater.com/spareparts-ia
Cause
Unit defective
Insufficient water circulation
Unit is not calibrated.
The heating capacity of the unit is
not sufficient with regards to the
ambient temperature or water vol-
ume to be heated up.
Value
230 V AC, 50 Hz
50 W
20 °C ... 33 °C
∅ 23 mm × 178 mm
Remedy
Check the mains voltage.
Replace unit
Check the temperature.
Set a slightly higher or lower
value than specified on the
scale.
Select a suitable unit.
biOrb Heater Set