b943293.book Seite 5 Mittwoch, 21. Dezember 2005 5:15 17
5. Again hold hand at a distance of approx. 5 - 10cm in front
of the sensor system.
The flow volumes are indicated via the indicator lamp in the
sensor system by groups of flashing signals separated
by a pause.
6. Flow volumes and display:
The number of flashing signals of the consecutive groups
corresponds to the following flow volumes:
1 = flow volume 1 litres
Pause
2 = flow volume 2 litres
Pause
3 = flow volume 3 litres (factory setting)
Pause
...
7 = flow volume 7 litres
Pause
After the group with 7 flashing signals, the routine starts
from the beginning
1 = flow volume 1 litres
...
7. Selecting the flow volume
The flow volume is selected by removing the hand from the
detection zone (at least 60cm) in the pause after a group
of flashing signals. Once the hand is removed, the fitting
immediately flushes with the selected flow volume
(the corresponding flashing signals are displayed
again during flushing).
8. The flow volume can be readjusted within the next 20 s
if necessary by again holding the hand at a distance
of 5 - 10cm in front of the sensor system (see point 5).
The selected flow volume is accepted as the new setting and
setting mode is automatically terminated if there is no hand in
front of the sensor system 20 s after flushing. The area directly
in front of the sensor system must be kept free from objects for
these 20 s as otherwise the flow volume will be unintentionally
adjusted once more.
Additional functions of the urinal fitting
The following settings can be made and changed
with the remote control (Prod. no.: 36 206):
Switch on/off 24-hour flush
(factory setting: switched on)
1. Press and hold the RESET button.
2. Then additionally press the OFF AUTO button within 2 s.
The indicator lamp in the sensor system of the fitting flashes:
– 4 x short = 24-hour flush is switched on,
– 2 x long = 24-hour flush is switched off.
No-use flush interval: 24 hours.
Switch on/off intermediate flush
(factory setting: switched on)
1. Press the TEST button => test mode is switched on.
2. Press the OFF AUTO button as required.
The indicator lamp in the sensor system of the fitting flashes:
– 4 x short = intermediate flush is switched on,
– 2 x long = intermediate flush is switched off.
Setting mode is quit by pressing the TEST button,
or automatically after 60 s.
Switch on/off pre-flush
(factory setting: switched off)
1. Press the TEST button => test mode is switched on.
2. Press the ON AUTO button as required.
The indicator lamp in the sensor system of the fitting flashes:
– 4 x short = pre-flush is switched on,
– 2 x long = pre-flush is switched off.
5
Setting mode is quit by pressing the TEST button,
or automatically after 60 s.
Set minimum delay time
(factory setting: 7 s)
1. Press the TEST button => test mode is switched on.
Using the + and – buttons (
delay time can be increased (+) or reduced (–).
2. Press the + or – button (
The indicator lamp in the sensor system of the fitting flashes:
– 4 x short = adjustment by one step (approx. 1 s),
– 2 x long = end position reached.
Setting mode is quit by pressing the TEST button,
or automatically after 60 s.
Maintenance
Inspect and clean all components and replace if necessary.
Shut off the water supply and switch off the voltage
supply.
Cleaning or replacing filter
1. Remove locking screw (E1), see Fig. [9].
2. Remove plate (E) upwards from frame (I), see Fig. [9].
3. Disconnect plug-in connector between solenoid valve (D)
and electronics (E), see Fig. [11].
4. Close isolating valve (H), see Fig. [12].
5. Remove solenoid valve (D), see Fig. [13].
6. Remove filter (K) and clean or replace, see Fig. [14].
7. Insert filter (K).
8. Fit solenoid valve (D), during this process pay attention to
the seals (D1) and the direction of flow, see Fig. [15].
9. Connect electronics (E) to solenoid valve (D), see Fig. [16].
10. Open isolating valve (H), see Fig. [7].
Assemble in reverse order.
Replacing solenoid valve
1. Remove locking screw (E1), see Fig. [9].
2. Remove plate (E) upwards from frame (I), see Fig. [9].
3. Disconnect plug-in connector between solenoid valve (D)
and electronics (E), see Fig. [11].
4. Close isolating valve (H), see Fig. [12].
5. Remove solenoid valve (D), see Fig. [13].
6. Fit new solenoid valve (D), during this process pay attention
to the seals (D1) and the direction of flow, see Fig. [15].
7. Open isolating valve (H), see Fig. [7].
Assemble in reverse order.
Replacing the transformer
Switch off voltage supply!
1. Remove locking screw (E1), see Fig. [9].
2. Remove plate (E) upwards from frame (I), see Fig. [9].
3. Disconnect plug-in connector between transformer (F)
and electronics, see Fig. [17].
4. Pull headpart (F) of the transformer off the base (G),
see Fig. [17].
5. Attach new headpart, see Fig. [18].
6. Connect electronics and transformer (F), see Fig. [18].
Assemble in reverse order.
Replacing the top plate with electronics
1. Remove locking screw (E1), see Fig. [9].
2. Remove plate (E) upwards from frame (I), see Fig. [9].
button), the minimum
button).