DC Voltage measurement / AC Voltage measurement
Attention!
DC voltage max. 1.000 V
AC voltage max. 750 V
1.
Set the rotary switch to the position V or mV
2.
Attach the pin-plug of the black test lead to the COM-jack and the pin-plug
of the red test lead to the multi-function jack.
3.
Touch the measuring points with the probe tips.
4.
Once
the
DC: If the polarity is reversed a "Minus sign" is displayed.
DC current / AC Current measurement
Note:
Avoid current measurements with the 10A setting for more than 30 seconds. This
can damage the device and / or the test leads.
1.
For measurements up to 6000 µA (mA) set the rotary switch to the µA
(mA)-Position and attach the pin-plug of the red test lead to the µA
(mA)-jack. For measurements up to 10 A set the rotary switch to the
A-Position and attach the pin-plug of the red test lead to the A-jack.
2.
Switch off the power source and open the circuit to be tested at the position
you are going to measure the current.
3.
Turn on the current and touch the measuring points with the test tips.
4.
Once
the
DC: If the polarity is reversed a "Minus sign" is displayed.
Resistance measurement, Continuity test, Diode test
Attention!
Before making any measurements, make sure the circuit is disconnected from
any power source and all capacitors are properly discharged!