Télécharger Imprimer la page

Nederman E-PAK 500 Manuel D'instruction page 36

Masquer les pouces Voir aussi pour E-PAK 500:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 150
EN
E-PAK 500
Control items
Connection – GND1
Connection – power cable, check tightness
Lightning conductor
Compressed air
Air lines cleaned
Air pressure (6–10 bar, 87–145 PSI)
Clean and dry air (ISO 8573-1, class 5)
Compressed air valve
Compressed air connected to unit
Ground check measurement
Check (≤100 ohm):
GND1 – Fan
Check (≤10
ohm):
5
Incoming duct – Incoming mains ground
GND1 – External mains ground
Accessories (if applicable)
Signs and warnings
Intended use marked or indicated
Safe bag replacement described or indicated
Initial start-up (function test)
Maintenance switch
Automatic start and stop (standby and reset switch), if fitted
Vacuum limiting valve (both, if two are fitted)
Motor, direction of rotation
Time spent in Y mode
Automatic filter cleaning
Manual filter cleaning
Cover on the start and control unit fitted
36
All manuals and user guides at all-guides.com
Result

Publicité

loading