Technical Data; Safety Instructions - Maico AKE 100 Notice De Montage Et Mode D'emploi

Déshumidificateur automatique des caves
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5. Technical data

See rating plate or Internet.

6. Safety instructions

General
● Assembly and electrical
connection may only be
undertaken by electricians in
accordance with chapter 1.
● Read these operating
instructions carefully before
commissioning.
● Only connect unit to perma-
nently wired electrical install-
lations with NYM-O or NYM-J
(3 x 1.5 mm² or 5 x 1.5 mm²)
cables. Mains isolation device
required with contact openings
of at least 3 mm at each pole.
● The unit may only be operated
using the voltage and frequen-
cy shown on the rating plate.
● Do not make any modifications
to the fan unit.
● Never operate unit without elec-
tronics cover [6] and cover [4].
Safe and correct practices
during operation
Danger of injury caused
by objects in the impeller.
Do not insert any objects
in the unit.
5. Technical data │ UK
Danger of injury from
rotating impeller. Do not
get too close to the fan
unit, to avoid hair,
clothing or jewellery being
drawn into the unit.
● Risks for people (including
children) with reduced physical,
sensory or mental capabilities
or a lack of knowledge. Fan
may only be installed,
commissioned, cleaned and
maintained by people who can
safely recognise and avoid the
risks associated with this work.
Children must not play with the
unit.
Supply air intake within the
living area
● The domestic air supply must
be set up so that virtually no
air from the kitchen, bathroom
and WC can flow into the
living areas in which the
AKE 100 is installed.
● A room from which the air has
to be extracted must be fitted
with a non-closable, free
supply air cross section of at
least 150 cm², e.g. with Maico
door ventilation grille MLK.
17

Publicité

Table des Matières
loading

Table des Matières