Scope Of Delivery; General Notes; Installation Staff; Symbols Used - Maico AKE 100 Notice De Montage Et Mode D'emploi

Déshumidificateur automatique des caves
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

UK │ 1. Scope of delivery

1. Scope of delivery

● Fan unit w ith internal climate sensor
● External shutter w ith external climate
sensor and sensor connection cable
● Tw o sealing strips
● These mounting and operating instructions

2. General notes

Read these mounting instructions
carefully before using the AKE.
Follow the instructions. Keep these
instructions safe for use later on.

2.1 Installation staff

Mounting is only permitted w hen carried out
by trained specialists.
Only qualified electricians are permitted to
make the electrical connections.
They are trained in electrical engineering and
are aw are of the risks and consequences of
an electric shock.

2.2 Symbols used

Direct risk of danger. Failure to
observe w ill result in severe
injury or death.
DANGER
Possibly dangerous situation
w hich could result in minor to
moderate injuries.
CAUTION
Possible situation w hich could
NOTICE
cause damage to the product or
its surroundings.
INFO symbol indicating
important information and tips.
Bullet point for information on the
respective subject.
Instructions. Follow the
1.
instructions given in the order
stated.
14

3. Product information

3.1 Unit overview, Figure A
1
Housing w ith motor
2
Impeller
3
Designer cover
4
Cover
5
Internal climate sensor
6
Electronics cover
7
Electronic circuit board
8
Internal grille
9
Cable grommet
10
External shutter – w all piece
11
External shutter – outer piece
12
External climate sensor w ith sensor
connection cable

3.2 Product description

AKE 100 is a small room fan for dehumidi-
fying rooms, especially cellars and other
similar rooms. The unit has a fixed internal
grille and is equipped w ith an integrated
internal climate sensor. A controlled dehumi-
dification takes place based on the compa-
rison betw een the room climate and the out-
door climate. To do this, an external shutter
w ith an integrated external climate sensor
MUST be connected. To aid in the room de-
humidification, an aeration fan from AKE 100
can directly be controlled at the same time.
Function of the dehum idification control
The controlled ventilation dehumidifies the
rooms (cellars) through targeted removal of
humid room air and simultaneous supplying
of dry outside air.
To do so, the absolute humidity (aH), as a
measure for the w ater vapour content in the
air, is determined by both climate sensors
(those for interior and exterior spaces).
This measurement takes place immediately
after sw itching on the unit. As soon as the
absolute outside humidity falls below the
absolute inside humidity (aH
fan of the AKE 100 is automatically activated
and a dehumidification period begins (active
time).
< aH
) the
outer
inner

Publicité

Table des Matières
loading

Table des Matières