Rev.2 14/01/2021
Pag.49
Remove the vermiculite
x1
Smoke conduit cleaning
! IMPORTANT
step
action
1
Open the hatches.
2
Clean the ashes, eventually use a brush or similar and reassemble everything.
Note: the hatches are equipped with gaskets, therefore, before reassembling them, make sure that the gaskets are not
worn.
1
All manuals and user guides at all-guides.com
Use and maintenance manual RBH 150 V - RBH 200 V
This operation must be carried out by a Ravelli Assistance Centre.
Schedule this type of cleaning with the Ravelli Assistance Centre.
The smoke conduit must be cleaned every 3 months.
x2
CLEAN UP
GASKET
INSPECTION HATCH