Metabo HPT WH 18DBDL2 Instructions De Sécurité Et Mode D'emploi page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
Before
charging
While
charging
Charge
indicator
lamp
(RED /
BLUE /
Charging
GREEN /
complete
PURPLE)
Overheat
standby
Charging
impossible
(2) Regarding the temperature of the rechargeable
battery.
The temperatures for rechargeable batteries are
as shown in the Table 3, and batteries that have
become hot should be cooled for a while before being
recharged.
Rechargeable
Temperatures at which the battery
batteries
BSL1860
BSL1830C
(3) Regarding recharging time (At 68°F (20°C))
Table 4 Charging time
Charger
Battery
BSL1860
BSL1830C
12
Indications of the charge indicator lamp
Lights for 0.5 seconds. Does not light
Blinks
for 0.5 seconds.
(RED)
(off for 0.5 seconds)
Lights for 0.5 seconds. Does not light
Blinks
for 1 second.
(BLUE)
(off for 1 second)
Lights for 1 second. Does not light for
Blinks
0.5 seconds.
(BLUE)
(off for 0.5 seconds)
Lights
Lights continuously
(BLUE)
Lights continuously
Lights
(GREEN)
(Continuous buzzer sound: about
6 seconds)
Lights for 0.3 seconds. Does not light
Blinks
for 0.3 seconds.
(RED)
(off for 0.3 seconds)
Lights for 0.1 seconds. Does not light
for 0.1 seconds.
Flickers
(off for 0.1 seconds)
(PURPLE)
(Intermittent buzzer sound: about
2 seconds)
Table 3
can be recharged
32°F – 122°F
( 0°C – 50°C)
UC18YSL3
Approx. 38 min.
Approx. 30 min.
Table 2
NOTE
The recharging time may vary according to the
ambient temperature.
4. Disconnect battery charger from the receptacle.
CAUTION
Do not pull the plug out of the receptacle by pulling
on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
5. Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out the
battery from the battery charger.
NOTE
Be sure to pull out the battery from the battery charger
after use, and then keep it.
Plugged into power source
Battery capacity at less than
50%
Battery capacity at less than
80%
Battery capacity at more than
80%
Battery overheated. Unable
to charge. (Charging will
commence when battery cools)
Malfunction in the battery or the
charger

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hpt wh 18dbdl2m

Table des Matières