(C) VERTICAL EXHAUST:
1.
Remove and save 2 screws from back edge and
3 screws from the top center of the Fan Cover
Bracket. Remove Fan Cover Bracket by sliding it
in the opposite direction of the arrow on the Fan
Cover Bracket as shown in Figure 11.
2.
Lift Hood Fan Unit carefully and slip wires out of
cavity. See Figure 12.
CAUTION: Do not pull or stretch hood fan
wiring.
Figure 11
3.
Rotate the Hood Fan Unit 90˚ so that the fan blade
openings are facing the top of the oven. See Figure
13 (A). Replace Hood Fan Unit into the oven. Be
careful not to pinch the lead wire between the inner
bracket and the Hood Fan Unit. Put the lead wire
into Wire Box. See Figure 13 (B).
4.
Replace the Fan Cover Bracket by sliding it into
the slits in the same direction as the arrow on the
Fan Cover Bracket. Make sure the fan blades are
visible through the top openings in the oven before
proceeding.
5.
Attach the Fan Cover Bracket to unit with the 2
screws from back edge and 3 screws from the
top center of the Fan Cover Bracket, which were
removed in Step 1 above. See Figure 14. The
Hood Fan Unit is now rotated for vertical exhaust
operation.
Figure 13
(A)
(B)
Rotate
90˚
6.
Attach the Exhaust Damper Assembly
fan cover on the top of the outercase cabinet by
sliding it into the slits in the same direction as the
arrow. Use 1 Tapping Screw 4 x 12 mm 4 from
the INSTALLATION HARDWARE and tighten into
place. See Figure 15.
All manuals and user guides at all-guides.com
Models MWOR530A2ASS, MWOR530A3ASS
OUTSIDE VENTILATION
Figure 12
Figure 14
8 to the
Figure 15
9. OVEN INSTALLATION
THIS OVEN CANNOT BE PROPERLY INSTALLED
WITHOUT REFERRING TO THE MOUNTING
INSTRUCTIONS FOUND ON WALL AND TOP
CABINET TEMPLATES.
THE NEXT STEP IS TO READ AND FOLLOW
MOUNTING INFORMATION ON WALL AND TOP
CABINET TEMPLATES. THIS OVEN MUST BE
ATTACHED TO AT LEAST ONE WALL STUD. SEE
2. WALL CONSTRUCTION ON PAGE 4.
WHEN DONE WITH TEMPLATES, PROCEED TO
MOUNTING SCALE PLATE SECTION.
MOUNTING SCALE PLATE
The Scale Plates are used to help locate the mounting
plate. Attach 2 Scale Plates 9 with tape (not included).
See Figure 16 and WALL TEMPLATE for locations.
After securing the mounting plate, remove and discard
the Scale Plates.
Figure 16
8
Scale Plates
Mounting Plate
Installation Manual