RADIO OR TV INTERFERENCE
Should there be any interference caused by the micro-
wave oven to your radio or TV, check that the micro-
wave oven is on a different electrical circuit, relocate
the radio or TV as far away from the oven as feasible or
check position and signal of receiving antenna.
4. HOOD EXHAUST DUCT
When the hood is vented to the outside, a hood exhaust
duct is required. All ductwork must be metal; absolutely
do not use plastic duct. Check that all connections are
made securely. Please read the following carefully:
EXHAUST CONNECTION: The hood exhaust has
been designed to connect to a standard 3-1/4" x 10"
rectangular duct. If round duct is required, a rectangu-
lar-to-round adapter must be used.
REAR EXHAUST: If a rear or horizontal exhaust is
to be used, care should be taken to align the exhaust
with the space between the studs, or wall should be
prepared at the time it is constructed by leaving enough
space between wall studs to accommodate exhaust.
MAXIMUM DUCT LENGTH: For satisfactory air move-
ment, the total duct length of 3-1/4" x 10" rectangular or
6" diameter round duct should not exceed 140 feet.
Elbows, adapters, wall caps, roof caps, etc. present
additional resistance to air flow and are equivalent to a
section of straight duct which is longer than their actual
physical size. When calculating the total length, add the
equivalent lengths of all transitions and adapters plus
the length of all straight duct sections. Figure 3 shows
the approximate feet of equivalent length of some typi-
cal ductwork parts. Use the values in parentheses for
calculating air flow resistance equivalent, which should
total less than 140 feet.
Figure 3
90˚ Elbow (10 ft.)
45˚ Elbow (5 ft.)
90˚ Elbow (25 ft.)
45˚ Elbow (5 ft.)
5. TOOLS RECOMMENDED FOR
INSTALLATION
Phillips Screwdriver
Electric Drill
All manuals and user guides at all-guides.com
Models MWOR530A2ASS, MWOR530A3ASS
10" Wide Elbow
Adaptor (5 ft.)
(10 ft.)
Wall Cap (40 ft.)
Roof Cap (24 ft.)
Pencil
Measure
Scissors
1/2", 5/8" and 3/32" Drill
Bits
1-1/2" Wood Bit or
Metal Hole Cutter (if
metal cabinet is used)
6. INSTALLATION HARDWARE
The INSTALLATION HARDWARE items 1 - 6 are in
a small bag. Items 7 - " are packed separately. All
items are in a small carton packed below the oven.
ITEM
NAME
Wood Screw
1
5 x 30 mm
Toggle Bolt with nuts
2
#10 - 24 x 50 mm
Top Cabinet Screw
3
5 x 60 mm
Tapping Screw
4
4 x 12 mm
Flat Washer 30 mm
5
diameter
6 Grommet
7 Rear Cushion
Exhaust Damper
8
Assembly
9 Scale Plate
! Grease Filter
" Bottom Sash
* Must use two - may use remaining four.
**May not use all depending on stud location.
Figure 4
Parts shown not to common scale.
Use with metal cabinets.
Surround the power cord
opening. Cut to fit.
Installation Manual
ENGLISH
Tape
Saw to cut exhaust opening
(if needed)
Protective Drop Cloth for
product and range - you
may also use carton for
protection
qTY
PART CODE
6*
XTSSD50P35000
4**
LX-BZ0195WRE0
2
XBRSD50P60000
8
XOTS740P12000
2
XWHSD50-16300
1
LBSHC0040MRE0
1
PCUSUB059MRP0
1
FFTA-B007MRK0
2
LANG-B004MRP0
2
PFIL-B014MRE0
1
HDEC-B001MRF0
5