6.- SAFETY
A number of possible risks may arise when
operating your solid fuel fireplace with fuel of any
brand.
The said risks can be minimised if the instructions
and recommendations included in this manual
are followed.
Below, we shall recommend some rules and
advice but, above all else, we recommend
common sense.
1. Keep any flammable material (furniture,
curtains, clothes...) away from fireplace, at a
safety distance of at least 90 cm.
2. Ash should be emptied into a metal
container and immediately removed from
the house.
3. Do not use flammable liquids to light the
fireplace.
4. Keep any type of flammable liquid (gasoline,
alcohol,....) at a distance from the cooker.
5. Periodically inspect the chimney and clean
whenever necessary.
6. Do
not
install
combustible or that feature any type of
lining that may be damaged or deformed by
high temperatures (varnish, paint...).
7. Gas, wood or pellet fireplaces heat up when
lit. As a result it is necessary to be cautious
and keep a certain distance away, especially
children, old people, people with special
needs and pets while the fire is on.
Make sure that children and anyone else not
used to the workings of a fireplace, are
supervised by an older person when near.
To avoid burns and also to protect vulnerable
people it is advisable to use a fireguard or screen.
The
use
of
heat
recommended when in contact with the
fireplace.
HERGÓM, rejects any liability derived from a
faulty installation or incorrect use and reserves
the right to alter its products without prior
warning.
All manuals and user guides at all-guides.com
near
walls
that
are
resistant
gloves
are
7. - FORCED CONVECTION. (Mod. H03
TURBOCONVECTOR)
7.1. INSTALLATION
 Ventilator
Install the ventilator in the preferred position
(see fig. 13) using the screws provided, if
position 2 or 3 is chosen remove the top and
place it together with the fibre joint in the
window of position 1.
In
both
cases, previously installed in the
cowling vibration of 6x80 screw
Set position by two nuts that accompany it,
leaving the set pressedhome against the cast
iron side as described in fig. 8izda.
For any of the positions fan pinch NTC
temperature probe between the fan frame
and
one
of
(recommended in one of the upper screws,
see fig. 8dcha).
Then connect the circuit to the power supply.
Check that the system operates properly as
explained in Section 7.2.
Air outlet to
other rooms
Air outlet to
other rooms
Air inlet for
THe fan.
Fig.-7 – Guide Diagram orientativo
17
provided
said
fastening
screws
Air outlet to
the room
Natural lining
convection outlet
Chimney
conduit
Air outlet
to the room

Publicité

loading

Ce manuel est également adapté pour:

H-03/70H-03/80