Only one setting is enabled between "DAILY TIMER" and "WEEKLY SCHEDULE". If any of the
pattern in "WEEKLY SCHEDULE" is set to ON, "DAILY TIMER" is disabled. "DAILY TIMER" can be
set across days, but "WEEKLY SCHEDULE" can't.
Users can set up to two timers, and set the ON or OFF time (set the interval of time to 10 minutes)
operation mode(there are heating, cooling and DHW modes for single pump; only cooling and
heating modes can be selected for multiple pumps, and it cannot be set as DHW mode ) and
temperature setting for each segment of timer.
It's invalid if the ON and OFF time are same. Display as follows:
Operating Introduction:
Press "▲" "▼" to select TIMER, ACT, TIME ON, TIME OFF, MODE, TWS or SILENT MODE. When
the cursor stays at "TIMER ", press "◄" and "►" to select "TIMER 1" or "TIMER 2". When it stays at
other items, we can also use " ◄", " ►" to adjust corresponding settings.
After setting, press "
previous interface.
If Time1 T.ON is set the same as Time1 T.OFF, then the setting is invalid, the ACT option for the timer
of this segment jumps to "OFF", the setting of Timer2 is the same as that of Timer1, and the timing
interval of Time2 can cross with that of Time1.
For example, if Timer1 T.ON is set to 12:00 and Timer1 T.OFF is set to 15:00, then the values of
Timer2 T.ON and Time2 T.OFF can be set in the range of 12:00-15:00. If the time interval crosses,
the machine will be powered on at the time T.ON which is set in Timer1 or Timer2, and will be
powered off at the time T.OFF which is set in Timer1 or Timer2.
After the daily timer function setting is enabled, there will be corresponding prompts displayed on
DAILY TIMER
Timer is useless.
The start time is same to
the end time.
OK
" to confirm saving, or press "
12
" to cancel setting and return to the
V.1