PROBLEM
Musty or unusual smell
Agitator does not turn
All manuals and user guides at all-guides.com
POSSIBLE CAUSE
• Smell of new motor
• Old and dirty filters
• The foam filter or exhaust
filter is wet.
• Switch is off (unit is in
bare floor mode)
• The power nozzle is
disconnected with the
wand.
• Agitator motor overload
protection is tripped
(brush is jammed)
• Belt broken
• The wand is disconnected
with the hose.
TROUBLESHOOTING
POSSIBLE SOLUTION
• New vacuum cleaner smell should
disappear in 1-2 months.
• Empty dust tank and clean filters.
• Dry the foam filter or exhaust filter
completely away from sunlight.
• Turn on agitator power switch.
• Properly connect the power nozzle to the
wand.
• Unplug the vacuum cleaner and check the
agitator for obstructions and reset the unit.
• Replace belt.
• Properly connect the wand to the hose.