To eliminate the risk of burns or fire from reaching over heated surfaces, cabinet storage space
located above the cooktop should be avoided. If cabinet storage is provided, risk can be reduced
by installing a range hood that projects horizontally a minimum of 5" (12.7 cm) beyond the
bottom of the cabinets. Never store flammable products in the drawer.
15" (38.1 cm)
Max. Depth
For Cabinet
Installed Above
Cooktop.
18" Min.
(45.7 cm)
B
24" Min.
(61 cm)
MODEL
30" Cooktop
30" (76.2 cm)
36" Cooktop
36" (91.4 cm)
Figure 2a – CABINET DESIGN
All manuals and user guides at all-guides.com
A
2" (5.1 cm) Minimum Distance
Between Rear Edge of Cutout and
Nearest Combustible Surface Above
Countertop.
*See Figure 2c
If a drawer is present underneath, allow
at least 6½" (16.5 cm) of clearance below
the counter top. Make sure there will be no
interference with gas or electrical connection.
A
B. Minimum
Clearance from
Left Side
12" (30.5 cm)
12" (30.5 cm)
CAUTION!
Clearance
C
C. Minimum
Clearance from
Right Side
12" (30.5 cm)
12" (30.5 cm)
34" (86.4 cm) Min.
Clearance Between
the Top of the Cooking
Platform and Unprotected
Wood or Metal Cabinet
Island Installation
1⅛"
(2.9 cm)
Figure 2b– Minimum
Recommended Distance From
Behind the Cabinet Front
Typical Installation
2"
(5 cm)
Figure 2c– Minimum Recommended
Distance Between Rear Edge of
Cutout and Nearest Combustible
Surface Behind Countertop
backsplash
Wall
7