Shutoff Valve -
Open position
Once regulator is in place, open the shutoff valve
in the gas supply line. Wait a few minutes for gas
to move through the gas line.
Check for leaks. After connecting the cooktop to
the gas supply, check the system for leaks with a
manometer. If a manometer is not available, turn
on the gas supply and use a liquid leak detector
(or soap and water) at all joints and connections
to check for leaks.
WARNING
Do not use a flame to check for leaks from gas
connections. Checking for leaks with a flame
may result in a fire or explosion.
Tighten all connections if necessary to prevent gas
leakage in the cooktop or supply line.
Check alignment of control knob valves after
connecting the cooktop to the gas supply to be
sure the cooktop manifold pipe has not moved. A
misalignment could cause the valve stems to rub
on the control panel, resulting in a gas leak at the
valve.
Disconnect this cooktop and its individual manual
shutoff valve from the gas supply piping system
during any pressure testing of that system at test
pressures greater than 1/2 psig (3.5 kPa or 14"
water column).
Isolate the cooktop from the gas supply piping
system by closing its individual manual shutoff
valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than 1/2 psig (3.5 kPa or 14" water column).
12
All manuals and user guides at all-guides.com
Figure 8
t o
g a
s s
u p
p l y
l i n
6. Electrical Requirements
120 volt, 60 Hertz, properly grounded branch
circuit protected by a 15 amp circuit breaker or
time delay fuse. Do not use an extension cord with
this cooktop.
Grounding Instructions
IMPORTANT: Please read carefully.
e
For personal safety, this appliance must be
properly grounded.
The power cord of this appliance is equipped with
a 3-prong (grounding) plug which mates with a
standard 3-prong grounding wall receptacle (see
Figure 9) to minimize the possibility of electric
shock hazard from the appliance.
The wall receptacle and circuit should be checked
by a qualified electrician to make sure the
receptacle is properly grounded.
Preferred Method
Grounding type
wall receptacle
Where a standard 2-prong wall receptacle is
installed, it is the personal responsibility and
obligation of the consumer to have it replaced by
a properly grounded 3-prong wall receptacle.
Do not, under any circumstances, cut or remove
the third (ground) prong from the power cord.
Disconnect electrical supply cord from wall
receptacle before servicing cooktop.
Do not, under any
circumstances,
cut, remove,
or bypass the
grounding prong.
Power supply cord with
3-prong grounding plug.
Figure 9
WARNING
AA-2194924-3