Rain sensor: we! ng the rain sensor let you entering rain alarm mode, the control unit will actuate the
automa" on. Dry the rain sensor and wait un" l the alarm fade on the control unit (7 minutes HELIOS KAIROS /
2 minutes PERGOLA MULTI LIGHT) before proceed with the tests of the others sensors.
Temperature sensor: the temperature thresholds are fi xed, informa" on from this sensor will be interpreted in
diff erent ways depending on the type of sensor and the control unit where it is leasnt, the thresholds are not
modifi able.
7
SENSORS ADJUSTMENT
The adjustment of the thresholds is made with the two trimmer:
20
Test Km/h
Wind sensor
The adjustment goes from few Km/h un" l 80Km/h
(160km/h PERGOLA). Se! ng a low value the
automa" on will react with low wind.
It is possible to disable the wind sensor turning the
trimmer fully clockwise.
ATTENTION disabling the wind sensor there is the
risk of damaging the automa• on.
8
DIAGNOSIS MODE
The diagnosis mode is used to test the func" oning of the sensor.
With the diagnosis mode it is possible to see the current state of the sensors and, se! ng the threshold of the
sensors, fi nd the current value of light and wind.
To enter the diagnosis mode it is necessary to press and keep pressed the bu& on (A) on the sensor for 10
seconds, un" l the led turns green. In this condi" on the led shows the state of the light sensor..
With another short pression the led turns amber and shows the state of the wind sensor.
With another short pression the led turns red and shows the state of the rain sensor.
With another short pression the led turns green and shows the state of the temperature sensor.
To exit the diagnosis mode press again the bu& on of the sensor or wait 5 minutes.
In this mode moving the trimmers it is possible to fi nd the transi" on threshold between the blinking led and
fi xed led, corresponding to the environmental condi" ons detected by the sensor at that " me.
SENSOR
LED COLOUR FIXED LED
Light
Green
Wind
Amber
Rain
Red
Temp
Green
6-1622652
rev3
All manuals and user guides at all-guides.com
40
60
Disabilitato
Below the set threshold
Below the set threshold
Below the set threshold
> 4°C ( > 2°C SA versions) < 4°C (< 2°C SA versions)
ITA
ENG
04/02/2016
Light sensor
The adjustment goes from few Klx un" l 60Klx. Se! ng
a low value the automa" on will open with low light.
The automa" on reacts with some minutes of delay
(almost 10) to the light varia" ons, to prevent frequent
movements during the day.
Rain sensor
The adjustement geos from few drops to heavy rain,
se! ng a low value the automa" on will react a% er the
fi rst drops, alarm fades when the sensor dries.
FAST BLINKING LED
Over the set threshold
Over the set threshold
Over the set threshold
FRA
ESP
DEU
POR
Test
Test
SLOW BLINKING LED
Not present
Sensor disabled
Not present
Not present
9/20