9
CHARACTERISTICS TABLE
Clima• c sensor
KAIROS
KAIROS SA
KAIROS DUO
KAIROS DUO SA
KAIROS PERGOLA
KAIROS PERGOLA SA
10
TROUBLESHOOTING
Problem
When the bu! on (A) is
pressed the is no blinking
from the LED
The automa" on doesn't
close when wind occurs
The automa" on closes
with low wind
The automa" on opens
too late in the morning
The automa" on opens
too early in the morning,
unwanted movements at
sunset
11
CHANGE THE IDENTIFICATION CODE OF THE SENSOR &ID'
Only in excep" onal cases. Changing ID will be necessary when there are two sensors working in the same area
and they have the same ID; this opera" on changes automa" cally the ID.
Press and keep pressed the bu! on on the sensor for more than 20 seconds, the led begins blinking red,green,
amber, when the led turns to green fi xed the changing of ID is complete and it is possible to release the bu! on.
Releasing the bu! on before the end of the procedure will abort the ID changing.
A! en" on a% er the ID changing it will be necessary to repeat the learning of the sensor on the control unit.
10/20
All manuals and user guides at all-guides.com
Power supply
100-240Vac
Photovoltaic panel
100-240Vac
Photovoltaic panel
100-240Vac
Photovoltaic panel
Possible causes
• Power failure
• Threshold set (trimmer) of the
wind sensor is too high
• Wrong inclina" on of the sensor
• Wrong se# ngs on the control unit
• Threshold set (trimmer) of the
wind sensor is too low
• Threshold set (trimmer) of the light
sensor is too high
• Threshold set (trimmer) of the light
sensor is too low
ITA
ENG
Consumpion
1.5W/12W heater
-
1.5W
-
1.5W/12W heater
-
Solu• ons
• Main supply versions: check the
• Rotate the wind trimmer
• Adjust the inclina" on so that the
• Check the control unit se# ngs
• Rotate the wind trimmer clockwise
• Rotate the light trimmer
• Rotate the light trimmer clockwise
FRA
ESP
DEU
POR
Transmission frequency
433.92 MHz
433.92 MHz
433.92 MHz
433.92 MHz
433.92 MHz
433.92 MHz
connec" ons
Photovoltaic panel versions: clean
the photovoltaic panel and leave
the sensor exposed to direct light
for at least 10/15 minutes
an" clockwise on a lower value
blades are in horizontal posi" on
on a higher value
an" clockwise on a lower value
on a higher value
6-1622652