Portable Heater Location
1. This portable heater is intended for outdoor use only.
Always ensure that adequate fresh air ventilation is
provided.
2. Always maintain proper clearance with combustible
materials, i.e. top 24 inches and sides 36 inches
minimum.
3. The heater must be put on a solid and stable surface.
4. Never operate the heater in an explosive atmosphere
like in areas where gasoline or other flammable liquids
or vapours are stored.
24"
36"
Testing for Leakage
Gas connections on this heater are leak tested at the
factory prior to shipment. Possible mishandling of this
appliance during shipping may impair product integrity.
A complete leakage test must be performed again at the
installation site. Please follow the procedure below.
1. Make a soap solution of one part liquid detergent and
one part water. The soap solution can be applied to
hoses and connections with a spray bottle, brush or rag.
2. Make sure that the safety control valve is in the "OFF"
position.
3. Turn the cylinder valve ON and check for soap bubbles
forming on and around connections and hoses. If bubbles
appear, there is a leak present.
4. If a leak is present, remove the gas cylinder immediately,
tighten any leaking fittings, replace the gas cylinder, and
recheck.
All manuals and user guides at all-guides.com
1. Perodically check the whole gas system for leaks.
2. Immediately check for leaks if an odour of gas is detected .
3. Extinguish all open flames during testing or when an odour
4. Never smoke while performing the leak test.
5. If you cannot stop a leak, unscrew and remove the cylinder
6. The heater must be checked with a full propane cylinder.
7. Use only manufacturer recommended replacement parts.
1. Open the valve on the gas supply cylinder completely.
2. Firmly press down and turn the variable control knob
3. Press down the variable control knob and hold for 20
4. If the pilot does not light, repeat step 2 to 3.
5. After the flame comes on, leave the variable control knob at
1. Turn control knob to "PILOT" position.
2. Press down lightly and turn to "OFF" position.
3.Turn the gas tank off completely.
Procedure for Leakage Test
of gas is detected.
from the heater.
DO NOT use the heater until you have performed a leak
test on all the connections and verified that your unit does
not leak.
Substitution may void the warranty.
Turning Heater ON
approximately 45°(counter clockwise).
seconds while holding down the variable control knob,
press the igniter button several times until the pilot flame
comes on. Release the variable control knob after the
pilot flame lights.
Note: If a new tank has just been connected, please allow at
least one minute for the air in the gas pipeline to purge out
through the pilot hole.
minimum position for about 5 minutes, then turn knob to set
desired heat level.
Turning the Heater and Pilot Light OFF
Variable Control Knob
7