Use only Hilti spare and accessory parts.
We cannot assume any liability resulting from the use of third-party parts.
Wear suitable protective equipment.
When pumping, always observe the pressure gauge to ensure the maximum operat-
ing pressure (→ Table 1 below) is not exceeded.
Before filling, after use and before maintenance work, allow the residual pressure in
the tank to dissipate completely (→ Section "After Use", Section 1).
Scope of delivery
Tank [1] with pump [2], Instructions for Use [3], and hose [4] (Fig. 1)
You will find the illustrations referred to above in the front fold-out pages 2 – 3 of these
Instructions for Use.
Technical data
Max. filling amount
Total contents
Max. operating pressure
Max. operating temperature
Weight when empty
Material of tank
Technical residual quantity
Table 1
Assembly
1. Connect the hose [4] to the outlet port [6].
Checks
Visual inspection:
Pay special attention to the connections between the tank – hose and to the condition of
the pump thread and hose.
No leaks:
Pump up the empty water supply device to 2 bar.
► The pressure must not decrease more than 0.5 bar within 30 minutes.
Function: Pull the red button on the safety valve [5]. (Fig. 2)
► The pressure must dissipate.
Making preparations
Observe the instructions in the section entitled "Safety".
1. Pull up the red button on the safety valve [5] until all excess pressure is released from
the tank. (Fig. 2)
2. Press the pump handle [7] down and turn it counterclockwise.
► The pump handle is locked in place. (Fig. 3)
3. Unscrew the pump [2] from the tank [1]. (Fig. 4)
4. Add the water to the tank [1] (Fig. 5)
5. Check the level [9] on the hose [4]. (Fig. 6)
Printed: 23.11.2017 | Doc-Nr: PUB / 5386587 / 000 / 00
All manuals and user guides at all-guides.com
Are tank [1], pump [2] and hose [4] undamaged? (Fig. 1)
Hilti DWP 10
10 l
13 l
6 bar
40 °C
5.2 kg
Steel with polyester coating
0.03 l