PROBLEM
Pressure reading on
the regulated pressure
gauge drops when an
accessory is used.
Compressor is not
supplying enough air to
operate accessories.
Regulator knob has
continuous air leak.
Regulator will not
shut off air outlet.
N000732
All manuals and user guides at all-guides.com
CAUSE
It is normal for "some"
If there is an excessive
pressure drop to occur.
amount of pressure drop
when the accessory
is used, adjust the
regulator following
the instructions in
the "Description of
Operation" paragraph in
the Operation Section.
NOTE: Adjust the
regulated pressure
under flow conditions
(while accessory
is being used).
Prolonged excessive
Decrease amount
use of air.
of air usage.
Compressor is not
Check the accessory
large enough for
air requirement. If
air requirement.
it is higher than the
SCFM or pressure
supplied by your air
compressor, you need
a larger compressor.
Hole in hose.
Check and replace
if required.
Check valve restricted.
Remove and clean,
or replace.
Air leaks.
Tighten fittings.
Damaged regulator.
Replace.
Damaged regulator.
Replace.
18 ENG