7.
Replace hose and new hose clamp.
8.
Perform the Break­in Procedure. See "Break­in Procedure" in the Operation
section.
TO REPLACE REGULATOR
1.
Release all air pressure from air tank. See "To Drain Tank" in the Maintenance
section.
2.
Unplug unit.
3.
Using an adjustable wrench
remove the gauges, quick
connect, and safety valve from
the regulator manifold.
4.
Remove the hose by removing
the hose clamp. NOTE: The
hose clamp is not reusable.
You must purchase a new hose
clamp, purchase a standard
hose clamp at a local hardware
store.
5.
Using an adjustable wrench
remove the regulator manifold.
6.
Apply pipe sealant to new
regulator manifold and assemble, tighten with wrench.
7.
Reapply pipe sealant to gauges, quick connect, and safety valve.
8.
Reassemble all components in reverse order of removal. Make sure to orient
gauges to read correctly and use wrenches to tighten all components.