Malfunction code
H8
F1
F2
F0
H3
E8
F4
Warning:
Turn off the air conditioner and
disconnect the power immediately
and contact the service center if the power
cord is overheated or damaged, or there is a
water leakage. Do not try to repair the device
yourself! Danger of electric shock and fire!
Cause
Chassis is full of water
Malfunction of ambient
temperature sensor
Malfunction of evaporator
temperature sensor
Refrigerant is leaking
System is blocked
Overloaded compressor
Overload malfunction
Outdoor tube temperature
sensor is open / short circuited
42
Solution
• R emove the water.
• I f malfunction persists, please
contact service center
Please contact service center
Please contact service center
• P ull the plug, wait for 30 min,
reinsert it and restart the device
• I f malfunction persists, please
contact service center
• C heck ambient temperature and
humidity. The ambient temperature
should not exceed 35° C
• C heck if evaporator or condenser
are blocked by objects. Remove
any obstacles, pull the plug, wait
for 3 min, reinsert it and restart the
device
• I f malfunction persists, please
contact service center
Please contact service center
Check after use:
Disconnect the power supply.
Clean filter and outer case.
Drain accumulated water in the chassis.