17. ERROR CODE
Below lists the errors that you may encounter and their description:
Codice Description
E
8101
Invalid data buffer
E
8102
Error while writing data
E
8103
Invalid CAN index/subindex
E
8104
Read-only CAN object
E
8105
Error while reading data
E
8106
Timeout expired while writing data
E
8107
Timeout expired while reading data
E
8108
MMS application not supported
E
8109
Data connection lost
E
8201
SD card not present
E
8202
SD card unformatted
E
8203
Error while reading data from file
E
8206
Missing data file
E
8209
Synergic table missing!
E
820c
SD update required!
E
8fa1
Menu creation aborted
E
8fa2
Hyerarchic menu creation aborted
E
8fa3
Parameters creation aborted
E
8fb1
Wrong configuration
Gas purge
W
4701
Warning which appears when the button is pressed purge gas
Antisticking
E
9001
Warning which appears when the output of the machine is short-circuited, MMA or TIG mode
Inverter overtemperature
E
9002
Warning which appears when the protection is hardware temperature of the inverter
Power supply error
E
9003
Warning which appears when the supply voltage exceeds the specified limits or when there are one or
more phases (three-phase machines only)
Thermal overload
E
9004
Warning which appears when the machine has passed the said duty cycle of Use
Water low pressure
E
9005
Signaling that appears when the pressure of the coolant is low, due to lack of the same liquid, presence
of air bubbles or air bubbles in the cooling circuit
AC group overtemperature
E
9006
Warning which appears when the protection is hardware assembly temperature for polarity reversal
Torch trigger pressed, release the torch trigger and / or verify proper operation
E
9010
Warning which appears when turning on the machine, the trigger is depressed
E= error
W= warning
17