WV4460E POWER VENT WATER HEATER CONTROLS
INSTRUCTIONS TO THE
HOMEOWNER
WARNING
Fire or Explosion Hazard.
Can cause severe injury, death, or property
damage.
Follow these warnings exactly:
1. IF YOU SMELL GAS:
a. Turn off the gas supply at the appliance ser-
vice valve. On LP gas systems, turn off the gas
supply at the gas tank.
b. Do not light any appliances in the house.
c. Do not touch electrical switches or use the
phone.
d. Leave the building and use a neighbor's phone
to call your gas supplier.
e. If you cannot reach your gas supplier, call the
fire department.
2. The water heater control must be replaced in
event of any physical damage, tampering, bent
terminals, missing or broken parts, stripped
threads, or evidence of exposure to heat.
WARNING
Scalding Hazard.
Can cause burns, severe injury, or death.
Never move temperature setpoint knob past the
B setting without checking water temperature at
the faucet, and re-adjusting until comfortably
warm to the touch. Consider the ages and health
of all who will come into contact with heated
water.
IMPORTANT
Follow the operating instructions provided by
the manufacturer of your water tank appliance.
The information in this form describes a typical
water heater control application, but the spe-
cific controls used and the procedures outlined
by the manufacturer of your appliance can dif-
fer, requiring special instructions.
WARNING
Electrical Shock Hazard.
Can cause severe injury, death, or property
damage.
Disconnect power supply before making wiring
connections to prevent electrical shock or
equipment damage.
Resideo Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
69-1872EF—03 M.S. Rev. 05-20 | Printed in United States
www.resideo.com
© 2020 Resideo Technologies, Inc. All rights reserved.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.
STOP: READ THE WARNINGS.
TURNING ON THE APPLIANCE
If the appliance does not turn on when the setpoint knob
is set several degrees above the previous temperature,
follow these instructions:
1. Set the temperature setpoint knob to its lowest
setting to reset the safety control.
2. Disconnect all electric power to the appliance.
3. Turn off the main gas supply to the appliance.
4. Wait five minutes to clear out any unburned gas. If
you then smell gas, STOP! Follow Step 1 in the
Warning above. If you DO NOT smell gas, continue
with the next step.
5. Turn on the main gas supply to the appliance.
6. Reconnect all electric power to the appliance.
7. Turn the setpoint knob to the desired setting.
8. If the appliance does not turn on, there may be
residual air in the gas supply line.
a. Set the temperature setpoint knob to its low-
est setting to reset the safety control.
b. Turn the setpoint knob to the desired setting.
c. Turn the Control's power switch to the OFF
position, then turn it back ON to restart the 90
second air-purge cycle for the gas supply.
9. If the previous step does not turn on the appliance,
turn off the main gas supply to the appliance and
contact a qualified service technician for assis-
tance.

TURNING OFF THE APPLIANCE

Shutdown
1. Turn device knob to LOW. Turn off the gas supply
to the appliance. Appliance will completely shut
off.
2. Follow the procedure in the Instructions To The
Homeowner section above to resume normal
operation.