AFETY INSTRUCTIONS
Please pay attention to the following before first time operation:
Never place the unit in direct contact with fire, gas, oxygen or hot objects such as hot plates.
Please observe the following during operation:
A. The handpiece may only be connected to the unit included in the delivery contents.
B. Grinding heads to be used:
• Standardized dental size: ø 2.332 – 2.350 mm (0.091 - 0.093 inches), shaft length 28 - 36 mm.
• Only use centered grinding heads with a rounded shaft end.
• The use of rusted or bent grinding heads is not permitted.
C. Use the speed controller carefully.
D. Appliance power supply: 100 VAC or 240 VAC.
E. Switch the unit off before you change the grinding head, and on Standby.
F. Take every precaution possible to ensure that the unit does not fall down or get damaged in any other
way.
G. If problems do arise with the handpiece, take it immediately to get it repaired.
H. Do not lubricate or wash the handpiece.
I.
Place the test grinding head in the chuck when storing the handpiece.
DE
J. For indoor use only.
K. Scrupulous supervision is required when the device is being used in the vicinity of children.
L. Always make sure that the filter chamber remains clean. This helps to prevent entering the dust or foreign
particles in the suction turbine and contaminate or even damage.
EN
M. Ensure that the device is not operated under the following conditions:
If no dust bag has been inserted
If a dust bag has been inserted incorrectly
FR
The filter bag is not regularly / timely changed (overfilled filter bag may burst!)
When the suction fan is demonstrably contaminated
N. If the filter bag is torn during the operation and a quantity of abrasive dust is present in the filter chamber,
the device should not be operated further otherwise the suction turbine will be damaged. In this case,
IT
send the unit immediately for service!
O. The filter bag is only meant for single use (disposable) and should not be emptied or used several times.
ES
DANGER!
Do not place the unit in direct contact with water or other fluids.
Never place or use the unit in a wet or moist environment.
NL
Do not touch the unit with wet hands.
Only operate the unit with the specified line voltage.
It is not permitted to use the unit outdoors.
RU
WARNING!
Children must not play with the device.
PL
Never leave the unit unattended when children or inexperienced persons are in its vicinity.
Only use the unit for the applications described in this manual.
Only use attachments and accessories from the manufacturer.
Never use the unit after the electrical lead has been damaged, when the unit has fallen down or when it has
SE
come in contact with water.
FI
Kaitstud / Secured by https://mereneid.eu/