9 Tool Address
Each 'Tool Plus' unit should be assigned an independent one of eight tool address.
This is important in a workshop where more than one power tool is being used at
the same time.
This information is used by the 'iVAC Pro Switch' to enable it to know the status
of each individual power tool in a system.
The Tool Address is set by means of the Program Switches 4, 5 and 6.
Tool Address
1
2
3
4
5
6
7
8 *
TP User Guide
S4
S5
on
off
off
on
on
on
off
off
on
off
off
on
on
on
off
off
S6
*
factory setting
off
off
off
on
on
on
on
off
10