Technical Data; Output Data; Switching Outputs - HYDAC ELECTRONIC EDS 601 Manuel D'utilisation

Manocontacteur électronique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

E
26

Technical data

5.
Input data
Measuring ranges
Overload pressures
Burst pressure
Mechanical connection
Torque value
Parts in contact with medium

Output data

Accuracy to DIN 16086,
Max. setting
(display, analogue output)
Repeatability
Temperature drift
Analogue output (optional)
Signal

Switching outputs

Type
Switching voltage
Switching current
Switching output
Switching cycles
Reaction time
Ambient conditions
Compensated temperature range -10 .. +70 °C
Operating temperature range
Storage temperature range
Fluid temperature range
mark
Vibration resistance to
DIN EN 60068-2-6 (0 .. 500 Hz)
Shock resistance to
DIN EN 60068-2-29 (1 ms)
Protection class to DIN 40050
Other data
Supply voltage
Current consumption
Switch-on current
Display
Connection supply voltage /
analogue output
Connection relay outputs
Housing material
Weight
Note: FS (Full Scale) = relative to the full measuring range
16; 40; 100; 250; 400; 600 bar
24; 60; 200; 500; 800; 1000 bar
200; 200; 500; 1000; 2000; 2000 bar
Threaded port G1/4 DIN 3852
20 Nm
Mech. connection: Stainless steel
≤ ± 0.5 % FS max.
≤ ± 1.0 % FS max.
≤ ± 0.5 % FS max.
≤ ± 0.05 % FS / °C max. zero point
≤ ± 0.05 % FS / °C max. zero range
(selectable)
4 .. 20 mA, ohmic resistance ≤ 400 Ω
0 .. 10 V, ohmic resistance ≥ 2 KΩ
2 relays with change-over contacts
max. 250 V
max. 2 A per switching output
max. 50 W / 400 VA
10 million without load
1 million with load
approx. 10 ms including electronics
-25 .. +70 °C
-25 .. +80 °C
-25 .. +80 °C
EN 61000-6-1 / 2 / 3 / 4
≤ 25 g
≤ 100 g
IP 65
20 .. 32 V DC
approx. 120 mA
approx. 1.5 A (100 ms)
4-digit, LED, 7 segment, red,
height of digits 13 mm
DIN 43650 / ISO 4400
(3 pole + PE)
DIN 43651
(6 pole + PE)
aluminium, anodised
approx. 300 g

Publicité

Table des Matières
loading

Table des Matières