Publicité

Liens rapides

FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
IMPORTANT
Electrostatic Discharge (ESD)
Sensitive Electronics
ESD problems are present everywhere. ESD may damage
or weaken the electronic control assembly. The new control
assembly may appear to work well after repair is finished,
but failure may occur at a later date due to ESD stress.
Use an anti-static wrist strap. Connect wrist strap to green
I
ground connection point or unpainted metal in the
appliance
Touch your finger repeatedly to a green ground
connection point or unpainted metal in the appliance.
Before removing the part from its package, touch the
I
anti-static bag to a green ground connection point or
unpainted metal in the appliance.
Avoid touching electronic parts or terminal contacts;
I
handle electronic control assembly by edges only.
When repackaging failed electronic control assembly in
I
anti-static bag, observe above instructions.
DIAGNOSTIC GUIDE
Before servicing, check the following:
Make sure there is power at the wall outlet.
I
Has a household fuse blown or circuit breaker tripped? Time
I
delay fuse?
Are both hot and cold water faucets open and water supply hoses
I
unobstructed?
All tests/checks should be made with a VOM or DVM having a
I
sensitivity of 20,000 ohms per volt DC or greater.
Check all connections before replacing components. Look for
I
broken or loose wires, failed terminals, or wires not pressed into
connections far enough.
A potential cause of a control not functioning is corrosion on
I
connections. Observe connections and check for continuity with
an ohmmeter.
Connectors: Look at top of connector. Check for broken or loose
I
wires. Check for wires not pressed into connector far enough to
engage metal barbs.
Resistance checks must be made with power cord unplugged
I
from outlet, and with wiring harness or connectors disconnected.
Verify unit operation by running a Service History Mode &
I
Diagnostic Test. See page 5.
PART NO. W10207732B
-OR-
POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE
AVERTISSEMENT
Déconnecter la source de courant électrique
avant l'entretien.
Replacer pièces et panneaux avant de faire la
remise en marche.
Le non-respect de ces instructions peut
causer un décès ou un choc électrique.
Circuits électroniques sensibles
aux décharges électrostatiques
Le risque de décharge électrostatique est permanent. Une
décharge électrostatique peut endommager ou affaiblir les
composants électroniques. La nouvelle carte peut donner
l'impression qu'elle fonctionne correctement après la
réparation, mais une décharge électrostatique peut lui avoir
fait subir des dommages qui provoqueront une défaillance
plus tard.
Utiliser un bracelet de décharge électrostatique. Connecter
I
le bracelet à la vis verte de liaison à la terre ou sur une
surface métallique non peinte de l'appareil
Toucher plusieurs fois du doigt la vis verte de liaison à la
terre ou une surface métallique non peinte de l'appareil.
Avant de retirer la pièce de son sachet, placer le sachet
I
antistatique en contact avec la vis verte de liaison à la terre
ou une surface métallique non peinte de l'appareil.
Éviter de toucher les composants électroniques ou les
I
broches de contact; tenir la carte de circuits électroniques
par les bords seulement lors des manipulations.
Lors du réemballage d'une carte de circuits électroniques
I
défaillante dans le sachet antistatique, appliquer les
instructions ci-dessus.
GUIDE DE DIAGNOSTIC
Avant d'entreprendre une réparation, contrôler ce qui suit :
Vérifier que la prise de courant est alimentée.
I
Fusible grillé ou disjoncteur ouvert? Fusible temporisé grillé?
I
Robinets d'eau chaude et d'eau froide ouverts et tuyaux d'arrivée
I
d'eau exempts d'obstruction?
Utiliser pour tous les contrôles un voltmètre ou autre instrument
I
dont la résistance interne est de 20 000 ohms par volt CC
ou plus.
Contrôler toutes les connexions avant de remplacer un composant.
I
Rechercher des fils brisés ou mal connectés, ou des bornes ou
cosses de connexion détériorées.
Le non-fonctionnement d'un organe de commande peut être dû à la
I
corrosion des pièces de connexion. Inspecter les connexions et
contrôler la continuité avec un ohmmètre.
Connecteurs : Examiner le sommet d'un connecteur; rechercher
I
des fils brisés ou mal connectés; rechercher également des cosses
mal branchées.
Lors de toute mesure de résistance, vérifier que le cordon
I
d'alimentation est débranché de la prise de courant, et que le
faisceau de câblage ou le connecteur est débranché.
Vérifier le bon fonctionnement de l'appareil : lancement du mode
I
Historique de réparation et du test de diagnostic. Voir page 5.
PAGE 1
Risque de choc électrique
IMPORTANT
-OU-
o
PIÈCE N W10207732B

Publicité

Table des Matières
loading

Sommaire des Matières pour Whirlpool WFW8300

  • Page 1 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE WARNING AVERTISSEMENT Electrical Shock Hazard Risque de choc électrique Disconnect power before servicing. Déconnecter la source de courant électrique avant l’entretien. Replace all parts and panels before operating.
  • Page 2: Troubleshooting Guide

    FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE TROUBLESHOOTING GUIDE GUIDE DE DIAGNOSTIC POSSIBLE CAUSE/TEST CAUSES POSSIBLES/TEST PROBLEM NOTE: Possible Cause/Tests must be performed in the NOTE : Pour chaque problème, on doit exécuter les opérations “Causes PROBLÈME sequence shown for each problem.
  • Page 3 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE TROUBLESHOOTING GUIDE GUIDE DE DIAGNOSTIC POSSIBLE CAUSE/TEST CAUSES POSSIBLES/TEST PROBLEM NOTE: Possible Cause/Tests must be performed in the NOTE : Pour chaque problème, on doit exécuter les opérations “Causes PROBLÈME sequence shown for each problem.
  • Page 4 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE TROUBLESHOOTING GUIDE GUIDE DE DIAGNOSTIC POSSIBLE CAUSE/TEST CAUSES POSSIBLES/TEST PROBLEM NOTE: Possible Cause/Tests must be performed in the NOTE : Pour chaque problème, on doit exécuter les opérations “Causes PROBLÈME sequence shown for each problem.
  • Page 5: Test De Diagnostic

    FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE DIAGNOSTIC TEST TEST DE DIAGNOSTIC The complete built-in service diagnostic module contains two Pour les tests de diagnostic, le module de diagnostic incorporé comporte entry modes and three modes of operation.
  • Page 6: Affichage De L'historique Des Erreurs

    électrique. HISTORY OVERVIEW TEST PROGRAM PROGRAMME DE TEST - PRÉSENTATION GÉNÉRALE Indication Actuators to Organe de commande Control Action Action de commande Whirlpool Whirlpool be Checked à contrôler Duet Sport Duet Sport Ht Door lock system Système verrou de porte...
  • Page 7: Programme De Test Manuel D'ensemble

    FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE MANUAL DIAGNOSTIC TEST TEST DE DIAGNOSTIC MANUEL The washer must be empty and the control must be in the Il faut que la laveuse soit vide et le module de commande doit être en position OFF state before pressing the touch-pad sequence to ARRÊT avant qu’on exécute la séquence de pressions sur les touches pour start the test.
  • Page 8 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE Pump Motor Resistance Test Test de résistance du moteur de pompe The resistance is measured from pin 1 to pin 2. La résistance est mesurée entre la broche 1 et la broche 2.
  • Page 9: Washer Care

    FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE ELECTRONIC ASSEMBLIES - REMOVAL CIRCUITS ÉLECTRONIQUES - DÉPOSE OU OR REPLACEMENT REMPLACEMENT IMPORTANT: Electrostatic (static electricity) discharge may cause damage to electronic control assemblies. IMPORTANT : Une décharge d’électricité...
  • Page 10 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE Washer Maintenance Procedure Entretien de la laveuse This washer has a special cycle that uses higher water Cette laveuse comporte un programme spécial qui utilise des volumes d’eau volumes in combination with liquid chlorine bleach to plus importants en combinaison avec l’agent de blanchiment liquide pour thoroughly clean the inside of the washer.
  • Page 11: Codes Affichés Pour Défaillance/Erreur

    FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE FAILURE/ERROR DISPLAY CODES CODES AFFICHÉS POUR DÉFAILLANCE/ERREUR The failure/error codes are displayed when accessing the Diagnostics Les codes de défaillance/erreur s’affichent lors de l’accès à la procédure test routine.
  • Page 12 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE DISPLAY EXPLANATION AND RECOMMENDED PROCEDURE DESCRIPTION ET MÉTHODE DE RÉPARATION RECOMMANDÉE AFFICHAGE LONG DRAIN DURÉE EXCESSIVE DE LA VIDANGE If the drain time exceeds 8 minutes, the water valves turn off. Si la vidange dure plus de 8 minutes, les électrovannes d’eau se ferment.
  • Page 13 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE DISPLAY EXPLANATION AND RECOMMENDED PROCEDURE DESCRIPTION ET MÉTHODE DE RÉPARATION RECOMMANDÉE AFFICHAGE DRIVE MOTOR TACHOMETER ERROR TACHYMÈTRE DU MOTEUR D'ENTRAÎNEMENT – ERREUR If the control is unable to properly detect motor speed, the machine shuts down.
  • Page 14 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE DISPLAY EXPLANATION AND RECOMMENDED PROCEDURE DESCRIPTION ET MÉTHODE DE RÉPARATION RECOMMANDÉE AFFICHAGE SERIAL COMMUNICATION ERROR COMMUNICATION SÉRIELLE – ERREUR La communication entre le module de commande central (MCC) et le module de commande du moteur The communication between the Central Control Unit (CCU) and the Motor Control Unit (MCM) ne peut pas s’effectuer correctement.
  • Page 15 FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE DISPLAY EXPLANATION AND RECOMMENDED PROCEDURE DESCRIPTION ET MÉTHODE DE RÉPARATION RECOMMANDÉE AFFICHAGE PUMP DRIVE SYSTEM ERROR ERREUR DU SYSTÈME D’ENTRAÎNEMENT DE LA POMPE When the connection between pump and the Central Control Unit (CCU) is Lorsque la connexion entre la pompe et le module de commande central (MCC) est coupée durant le programme de vidange.
  • Page 16: Wiring Diagram

    FOR SERVICE TECHNICIAN ONLY - DO NOT REMOVE OR DESTROY POUR LE TECHNICIEN SEULEMENT - NE PAS ENLEVER NI DÉTRUIRE WIRING DIAGRAM SCHÉMA DE CÂBLAGE DRIVE MOTOR Moteur d’entraînement Dispenser Heating Element Inlet Valves Distributeur DOOR LOCK/SWITCH Élément chauffant Drain Pump Contacteur/verrou de porte Électrovannes Motor Switch...

Ce manuel est également adapté pour:

Wfw8400Wfw8410Wfw8500