Basic Operation; Indicator Lights - Tripp-Lite SmartPro INT 450 Manuel De L'utilisateur

450-1500 va onduleur intelligent ligne interactive (230v)
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Basic Operation

Switches
System Enable Switch
This switch activates the battery charger and intelligent micro-
processor. Always leave it in the "ON" (or "ENABLE/I") position
when your UPS is plugged in. Set the System Enable Switch to
"OFF" (or "DISABLE/O") only if you store or ship your UPS (to
reduce battery drain).
Note: the "XXX" light will flash until you engage the ON/Standby Switch to activate
the "ON" mode (power ON at the UPS receptacles).
ON/Standby Switch
This momentary switch controls power to the UPS receptacles.
Engage it momentarily and release it to toggle between the "ON"
mode (power ON at the UPS receptacles) and "Standby" mode
(power OFF at the UPS receptacles).
Mute/Test Switch
Use this momentary switch to do two things:
Silence the UPS On Battery alarm
Engage this switch and release it to silence the UPS on Battery
alarm, a series of short beeps that sounds intermittantly when
the UPS is providing AC power from battery. Note: when the
battery is nearly depleted, the Low Battery alarm, a continuous
beep that cannot be silenced, will alert you to immediately shut
down connected equipment.
Test your UPS's battery charge
Leave your connected equipment ON. With your UPS plugged in
and completely turned ON, engage this switch; hold it there for
5 seconds and release it. You will hear a series of short beeps as
the UPS momentarily switches to battery to test its charge. The
"
will sound if your UPS fails a self-test and/or the UPS battery is
less than fully charged. If this occurs, let the UPS charge for 12
hours and perform a second self-test. If the light continues to stay
on, contact Tripp Lite for service. CAUTION: Do not unplug your
UPS to test its batteries. This will remove safe electrical grounding
and may introduce a damaging surge into your network connections.

Indicator Lights

Light descriptions apply when the UPS is plugged into a wall outlet and turned ON.
This green light will shine constantly to indicate AC power is
available at the receptacles. It will flash to indicate AC power is
not available. (See "System Enable Switch" and "On/Standby
Switch" descriptions above.)
This multi-colored light displays 7 separate UPS battery charge
conditions. It will turn from red (low) to yellow (medium) to green
(full) to show you the level of battery charge. If the light is
constant, your UPS is operating from line power, and the battery is
charging. If the light is flashing, your UPS is operating from battery
power, and the battery is discharging. When the light flashes red,
close any files you are working on and shut down your computer.
4
" light will turn ON and the alarm (a long, continuous beep)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Smart int 700Smart int 1000Smart int 1500

Table des Matières