Télécharger Imprimer la page

Publicité

Liens rapides

Installation guide
Electric expansion valve
Types AKV 10P, AKV 10PS
Refrigerants :
R744, R22, R23, R134A, R404A, R407A, R407C,
R407F, R410A, R422B, 422D, R448A, R449A,
R449B, R450A, R452A, R507, R513A.
For other refrigerants, please contact Danfoss.
Max. operating pressure differential:
MOPD , P1- P2 :
AKV 10P0 - AKV 10P6 = 35 bar / 505 psi
AKV 10P7 = 18bar / 260 psi
AKV 10PS4 - AKV 10PS7 = 35 bar / 505 psi
If operated consistently at or near MOPD, the service interval will decrease.
Erfolgt der Betrieb dauerhaft mit oder in Nähe des MOPD, verkürzt sich das Wartungsintervall.
En cas d'utilisation constante à une valeur proche ou égale de la MOPD, l'intervalle d'entretien
diminuera.
Si el funcionamiento tiene lugar constantemente a la presión MOPD o cerca de la misma, las labores
de mantenimiento deberán tener lugar con más frecuencia.
Se utilizzata frequentemente alla MOPD, o livello simile, l'intervallo di manutenzione diminuirà.
Se operada de maneira consistente no MOPD ou perto dele, o intervalo de serviço diminuirá.
如果在MOPD(最大开通压差)条件下或其附近范围持续作业,检修间隔会缩短
В случае непрерывной работы при максимальном перепаде давления открытия
периодичность технического обслуживания сокращается.
Mounting height
Min. 65 mm / 2.6 in
Tube length / dimensions
AKV 10P
© Danfoss | DCS (az) | 2018.06
Max. working pressure :
PS: 90 barg / 1305 psig
Max. test pressure:
PT: 135barg / 1958 psig
Media temperature range:
t
-50 °C / -58 °F
min.
t
60 °C / 140 °F
max.
Mounting orientation
AKV 10P0 - AKVP7
L > 7 x Ø
Ø
ENGINEERING
T O M O R R O W
English, German, French, Spanish, Italian,
Brasilian, Portugese, Chinese, Russian
Continuous operation temperature
COT: 60 °C / 140 °F
Max. abnormal pressure
MAP: 90 bar / 1305 psig
Ambient temperature range:
t
-50 °C / - 58 °F
min.
t
max.
Brazing
Permanent
magnet coil
code no.
018F0091
Tube length / dimensions
AKV 10PS
Filter
Mandatory
< 40 µm/micron
50 °C / 120 °F
Min. 5% Ag
Max. 125 °C / 257 °F
N
2
AKV 10PS4 - AKV 10PS7
L > 7 x Ø
Ø
DKRCC.PI.VA1.L3.ML | 1
P1
P2

Publicité