Fireplace insTallaTion
Continued
Wiring Instructions
1. Remove electrical cover plate with bushing
from fireplace by removing 2 sheet metal
screws as shown in Figure 7, page 6.
2. Slide power source wiring through electrical
bushing opening and electrical cover plate
and make all necessary connections.
3. Slide all wiring connections in electrical
housing as shown in Figure 7, page 6.
4. Secure electrical cover plate with screws
previously removed.
Note: Electrical housing and cover plate have
sharp edges. Wear protective gloves.

VenTing insTallaTion

OPTIONAL OUTSIDE AIR KIT
(MODEL AK4/AK4F)
Installation of outside air kit should be per-
formed during rough framing of fireplace due
to the nature of it's location. Outside combus-
tion air is accessed through a vented crawl
space (AK4F) or through a sidewall (AK4).
See Figure 25 on page 15 for instruction of
operating air kit.
CAUTION: Combustion air
inlet ducts shall not terminate
in attic space.
The maximum height for the
air vent can not exceed 3 feet
below the flue gas outlet of the
termination.
Secure to Collars with Metal Tape, Screws
or Straps (Min. of 1/4" x 20" in size)
Vented Crawl Space
(Check Local Codes
Before Installing in a
Vented Crawl Space)
Figure 8 - Outside Air Kit
107826-01K
Air Inlet
Location
Must Allow
For Bushes
or Snow
Air Inlet
Eyebrow
Vent Hood
Required for
Wall Installation
www.fmiproducts.com
CHIMNEY PIPE
FMI PRODUCTS, LLC chimney system
consists of 12", 18", 24", 36" and 48" snap-
lock, double-wall pipe segments, planned
for maximum adaptability to individual site
requirements. Actual lengths gained after fit-
ting overlaps must be taken into consideration
(lineal gain) and are given in lineal gain chart
(see Figure 9). Lineal gain is actual measur-
able length of a part after two or more parts
are connected. For Canada, use chimney parts
designated "HT".
12
/
"
3
8
Galvanized
Outer Pipe
8" Stainless
Inner Pipe
LINEAL GAIN
PART NO.
DESCRIPTION
36"
12-8DM
Pipe Section
12-8HT
18-8DM
Pipe Section
18-8HT
24-8DM
Pipe Section
24-8HT
36-8DM
Pipe Section
36-8HT
48-8DM
Pipe Section
48-8HT
RT-8DM
Round Termination
RTL-8DM
Round Termination
Round Termination
RTT-8DM
with Slip Section
Round Termination
RTTL-8DM
with Slip Section
ET-8DM
Square Chase-Top
Square Chase-Top
ETO-8DM
Square Chase-Top
ETL-8DM
with Slip Section
Square Chase-Top
ETLO-8DM
with Mesh & Slip
* The lineal gain for the terminations is
measured to the flue gas outlet height.
Figure 9 - Lineal Gain
Hemmed
End
GAIN
Fireplace
37
10
16
23
34
46
6
7
6
23
8
21
with Mesh
7" to 15"*
12" to
25
Section
/
"
1
2
/
"
5
8
/
"
5
8
/
"
5
8
/
"
5
8
/
"
5
8
/
"*
7
8
/
"*
3
4
/
" to
7
8
/
"*
1
8
/
" to
1
2
/
"*
1
2
12"*
12"*
/
"*
1
2
7