CONTROL PADS ON THE DEHUMIDIFIER
Display
8 8
Shows the set % humidity level from 35% to 85% or
auto start/stop time (0~24) while setting, then shows
the actual (
5% accuracy) room % humidity level
in a range of 30%RH(Relative Humidity) to 90%RH
(Relative Humidity).
Error Codes and Protection Codes:
AS- Humidity sensor module error--Unplug the unit
and plug it back in. If error repeats, call for service.
Other features
Bucket Full Light
Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not replaced in the proper position.
Auto Shut Off
The dehumidifier shuts off when the bucket is full,
or when the bucket is removed or not replaced in
the proper position. For some models the fan
motor will continue operating for 30 seconds.
Auto Defrost
When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.
NOTE:When Auto defrosting operation,the unit may
make a voice of refrigerant flowing,it is normal.
Wait 3 minutes before resuming operation
After the unit has stopped, it can not be restart
opertation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.
Smart dehumidifying mode(optional)
At smart dehumidifying mode, the unit will
automatically control room humidity in a
comfortable range 45%~55% according to the
room temperature. The humidity setting
function will be invalid.
Auto-Restart
If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automa-
tically when the power resumes.
ES- Temperature sensor error-- Unplug the unit and
plug it back in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position-- Empty
the bucket and replace it in the right position.
Setting the Timer
Press to initiate the Auto start or Auto stop feature, in
conjuction with the
When the unit is on, press the Timer pad to actieve
the AUTO STOP featrue. When the unit is off, press
this button to actieve the AUTO START feature.
Press or hold the UP or DOWN pad to change the
Auto time by 0.5 hour increments, up to 10 hours, then
at 1 hour increments up to 24 hours. The control will
count down the time remaining until start.
The selected time will register in 5 seconds and the
system will automatically revert back to display the
previous humidity setting.
Turning the unit ON or OFF at any time or adjusting the
timer setting to 0.0 will cancel the Auto Start or Auto
Stop feature.
When LED display window displays the code of P2, the
Auto Start or Auto Stop feature will also be cancelled.
36
and
pads.