Electrical Connection - Faber CITY EG5 WH/X F60 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15
RECIRCULATION VERSION AIR OUTLET
To install the Recirculation Version of the hood, the optional
Activated charcoal cartridge kit must be purchased.
• Screw the filter cover onto the air outlet, using four screws 12c
(2.9 x 12.5).
• Fix the directional grille 8 on the recirculation air outlet using
the 2 screws 12d (2,9 x 9,5) provided.

ELECTRICAL CONNECTION

• Connect the hood to the mains through a two-pole switch
having a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being
sure that the connector of the feeding cable is correctly inserted
in the socket placed on the side of the fan.
The chimney can only be installed with exhausting hood
• Fasten the angle iron 15 to the hood canopy using the screws
12d (2,9 x 9,5) provided.
Upper exhaust flue
• Slightly widen the two sides of the upper flue and hook them
behind the brackets 7.2.1, making sure that they are well
seated.
• Secure the sides to the brackets using the 4 screws 12c (2,9 x
6,5) supplied.
Lower exhaust flue
• Slightly widen the two sides of the flue and hook them
between the upper flue and the wall, making sure that they are
well seated.
• Fix the lower part laterally to the hood body using the 2 screws
12c (2,9 x 6,5) supplied.
EN
Flue assembly
12d
8
12c
16
1
10
0