Porter Cable 513 Manuel D'instructions page 12

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Disconnect tool from power source!
5.
Turn the mortiser crank handle until the bit is in the top-most position.
6.
Place the mortiser on the door so that the top edge of the bit touches the line
drawn on edge of the door.
7.
Mortise the door as instructed in "MAKING A TRIAL CUT".
PRODUCTION LOCK MORTISING
If you have a number of doors with the locks at the same height, the height-rod
attachment (Fig. 11) can be of great value. After you have determined the correct
height, and have the lock mortiser in position on the first door, attach the four
rods that compose the height-rod attachment. Insert the rods in the mortiser and
place the height rod stop (G) on the top of the rod so that it rests on the top of the
door. Lock the height-rod screws (H) Fig. 12. To locate the mortiser on the next
door, place the mortiser on the door with the height-rod stop resting on the top
of the door and tighten the clamps. This will assure having all locks located in the
same position.
MODEL 517 LOCK FACE TEMPLATE
REQUIRED EQUIPMENT (Router and Template)
42024 Template Guide (included)
42237 Locknut (Included)
43440PC 5/8" (15.9 mm) Diameter Straight Bit (not included)
Setting up the template
1.
Loosen the locking screw (A) Fig. 13.
2.
Adjust the side guides (C) Fig. 13, so that the space between them is 1/8"
(3.2 mm) wider than the lock face.
3.
Firmly tighten the screw (A).
4.
Loosen the locking screw (D) Fig. 13.
5.
Adjust the distance between (E) and (B) to 1/8" (3.2 mm) longer than the lock
face.
6.
Firmly tighten the screw (D).
G
Fig. 11
12
H
Fig. 12

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

517