EPCO-...-KF
3
Transport and storage
Consider the weight of the electric cylinder with guide unit.
Depending on the version, the EPCO-KF weighs up to 8 kg.
4
Installation
4.1
Mechanical installation
Mount cylinder
Do not modify the screws and threaded pins if not directly requested to do so in these operating
instructions.
Make sure that the device is installed free of mechanical stress and deflection (evenness of the
bearing surface: ≤ 0.2 mm).
Position the EPCO-KF so that all of the operating elements are accessible.
Mount the EPCO using the mounting accessories.
Tighten the mounting screws evenly.
Interfaces for mounting components
on the profile
With screws
1) è www.festo.com/catalogue
Fig. 2
Size
Direct mounting 4 / 7
Thread
Max. tightening torque
Centring holes
Slot nut mounting 6
Max. tightening torque
Tab. 1
10
With slot nuts NST
16
M5 (M6 for through-hole)
[Nm]
4 (6)
7H8 / 9H8
[mm]
[Nm]
1.5
1)
25
40
5
5
Festo – EPCO-...-KF – 1506NH English