BTL7-A/C/E/G50_-M_ _ _ _ -T_2/3-S32/S135/KA_ _/FA_ _
Magnetostrictive Linear Position Sensor – Rod Style
4
Installation and connection (continued)
Magnet
(e.g. BTL-P-1028-15R)
Supporting rod made of non-magnetizable material
Fig. 4-9:
Example 2, BTL installed with supporting rod (only for
BTL7...-TB/TZ....)
4.4.1
Connector S32/cable connection
S32
Pin
Wire color
1
YE yellow
2
GY gray
3
PK pink
4
RD red
5
GN green
6
BU blue
7
BN brown
8
WH white
Tab. 4-2:
Connection assignment BTL7-A/C/E/G504-...-S32/cable
S32
Pin
Wire color
1
YE yellow
2
GY gray
3
PK pink
4
RD red
5
GN green
6
BU blue
7
BN brown
8
WH white
Tab. 4-3:
Connection assignment BTL7-A/C/E/G505-...-S32/cable
1)
Unassigned leads can be connected to the GND on the controller side but not to the shield.
Factory setting, can be freely configured with the PC software.
2)
Reference potential for supply voltage and EMC-GND.
3)
www.balluff.com
BTL7-... interface
-A504
-G504
Not used
0
1)
0 V
Not used
La (communication line)
0
10 V
10
10 V
2)
–
2)
...
...
GND
3)
10
30 V
...
Lb (communication line)
BTL7-... interface
-A505
-G505
Not used
20
1)
0 V
Not used
La (communication line)
10
0 V
10
10 V
2)
–
2)
...
...
GND
3)
10
30 V
...
Lb (communication line)
4.4
Electrical connection
Depending on the model, the electrical connection is made
using a cable or a connector (BTL7...-S32, BTL7...-S135)
The connection or pin assignments for the respective
version can be found in Tables 4-2 to 4-5.
Note the information on shielding and cable
routing on page 12.
-C504
-E504
20 mA
4
20 mA
2)
2)
...
...
Fig. 4-10: Pin assignment of S32
1)
Not used
1)
-C505
-E505
0 mA
20
4 mA
2)
2)
...
...
Fig. 4-11: Pin assignment of S32
1)
Not used
1)
connector (view from above on
BTL), 8-pin M16 circular plug
connector (view from above on
BTL), 8-pin M16 circular plug
english