Installation
The unit should be mounted via its screw holes on the bracket. Always ensure that the unit is firmly fixed to avoid
vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and
able to support a weight of 10 times of the unit's weight.
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run
synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels
required by all fixtures on a serial data link determines the number of fixtures that the data link can support.
Important: Fixtures on a serial/data link must be daisy chained in one single line. Maximum recommended serial data
link distance: 500 meters (1640 ft.) Maximum recommended number of fixtures on a serial data link: 32 fixtures
Data Cabling
To link fixtures together you must use data cables. If you choose to create your own cable, please use data-grade cables
that can carry a high quality signal and are less prone to electromagnetic interference.
CABLE CONNECTORS
Cabling must have a male XLR connector on one end and a female XLR connector on the other end.
DMX connector configuration
Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to
connect a DMX signal terminator.
4. How To Control The Unit
Master mode: any unit can work as a master
Slave mode: the DMX address value must be set to Slave.
DMX code setting: d1~d512
SETTING MENU LED DISPLAY:
MENU
DO01-D512 DMX mode, change the numerical value via the UP & DOWN keys
CC01-CC64 Color selection, select different colors via the UP & DOWN keys
RB01-RB16 Color fade, change speed via the UP & DOWN keys, the higher the value, the faster
PL01-PL16 Color pulse transform, change speed via the UP & DOWN keys. The higher the value, the faster
SD01-SD16 Color transition, change speed via the UP & DOWN keys. The higher the value, the faster
FL01-FL16 Flash mode
©Copyright LOTRONIC 2017
Description
PARTY-PAR181
Resistance 120 ohm
between pin 2 (DMX-)
and pin 3 (DMX+) of the
last fixture.