During pipe cleaning never leave the machine unobserved!
Secure the operation site (the road, the shaft) so that no uninvolved persons suffer injuries and
always cover open shafts or gullies.
Check the area to be investigated with a gas warner for the presence of poisonous or explosive
gases!
The machine and the accessories should be cleaned and disinfected after every use.
The recommended personal protective equipment should be worn whenever any work is done:
safety glasses, safety helmet, safety shoes, safety vest!
The hands should be cleaned and disinfected after every activity; there is increased risk of infec-
tion by pathogens!
1.3
Residual risks
Even when observing all of the safety instructions there are still some residual risks remaining,
for example: spirals can overturn (create a loop if the operating arc is too large) thereby creating
the risk of clamping. Spirals under tension can spring out of the pipe ~ a risk of injury!
1.4
Intended use
The pipe cleaning machines may only be used to clean pipes of the following diameters:
13 mm spiral: 70-100 mm; 16 mm spiral: 70-125 mm; 20 mm spiral: 150-250 mm
The pipe cleaning machines are only designed for short term operation and may therefore only
be operated without interruption for a maximum of 15 minutes! Do not use this product in any
other way as stated for normal use!
2
Technical Data
Voltage .............................................................. 230 V, 110 V, 120 V – 50/ 60 Hz
Output P1 .......................................................... 620 W
Dimensions (L x W x H) ..................................... 700 x 550 x 870 mm
Weight (with Ø 20 mm spiral) ............................. about 68 kg
Spiral type ......................................................... Ø 13 mm ..........Ø 16 mm ......... Ø 20 mm
Pipe diameter working range ............................. 70-100 mm .......70-125 mm ...... 150-250 mm
Max. spiral length drum M .................................. 15 m .................15 m ................ -
Max. spiral length drum L ................................... 30 m .................30 m ................ 20 m
Max. working length ........................................... 30 m .................45 m ................ 60 m
Speed of the spiral
(according to the pipe route) .............................. ca. 5 m/min ...... ca. 6,5 m/min... ca. 8,5 m/min
Direction of rotation (switch position I) ................ left (looking from the front onto the drum)
Protection type ................................................... IP X4
Operating mode ................................................. S2 15 min.
Noise pressure level (L
Sound power level (L
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 62841-1.
Vibration total value ........................................... ≤ 2,5 m/s
The Vibration Total Value quoted in these instructions and the quoted noise emission values
were measured according to standardized measurement procedures and can be used to com-
pare one electric power tool with another. They can also be used to make an initial estimate of
the loading.
The quoted vibration and noise emissions can vary during actual use of the electric
power tool dependent on the way in which the electric power tool is used, in particular
what type of workpiece is being processed. Establish additional safety measures to
protect the operator which are based upon an estimate of the vibration loading during the actual
usage conditions (in doing so taking account of parts of the operating cycle, for example times in
14
) .................................. 79 dB (A) ¦ K
pA
) .................................... 90 dB (A) ¦ K
WA
ENGLISH
3 dB (A)
pA
3 dB (A)
WA
2
2
¦ K= 1,5 m/s