Step 2: (Guide pipe must only be fi tted with refi t version!)
B4
US/GB
B5
B6
B7
Step 3: (Installation of front system)
B8
B9
14/64
B4-B7:
If the lower and upper guide pipes are supplied separa-
tely, the two pipes must be connected using the adhesive
supplied together with the accessories. The adhesive is
applied to the guide pipe with the thread at the end with–
out the thread in a suffi cient quantity such that the front
area of the aperture is well fi lled. The guide pipe with the
pin should now quickly be pushed into the other pipe. The
connected pipes should now be left to harden for 10-15
minutes.
Important: The same-length pairs
NOTICE!!!
should always be connected!
B8:
Remove door rubber seal around A-column cladding.
B9:
Remove upper cladding beginning from the A-column. Clips
are released automatically. Remove cladding moving up-
wards.