photocells work both when the gate opens (by
starting the opening movement again after half a
second time), and when It closes (by starting the
reverse movement after one second time).
If DIP 6 is ON => If there Is an obstacle within the photocells range of
action when the gate is closed and its opening Is
commanded, the gate opens (during Its opening,
photocells do not work). Photocells work only while
the gate Is closing (by starting Its reverse motion
after one second, even if they are still engaged).

STOP BUTTON

The STOP button stops the gate during any operation.
If you push it when the gate is totally open (or partly open, by using the
pedestrian command), this button temporary excludes the automatic
closing (if selected by DIP3 and DIP9). It Is than necessary to operate
another command to make the gate close again.
The automatic closing function Is enabled again with the following
operating cycle (if selected by DIP3 and DIP9).
BLINKER
N.B.: This electric board can supply power ONLY TO BLINKERS
WITH (ACG7059) BLINKING CIRCUIT, with max. 40W lamps.
PRE-BLINKING FUNCTION:
- With DIP8 on OFF => the motor, the blinker and the buzzer start at the
same time.
- With DIP 8 on ON => the blinker and the buzzer start 3 seconds
before the motor.
BUZZER (Optional)
Current as supplied for buzzer operation 200 mA 12Vdc.
The buzzer emits an intermittent sound signal during opening and
closing cycles. When safety devices are operated (alarm), the
intermittence frequency of this sound signal Increases.
WARNING LIGHT - GATE OPEN (COM-SIGNAL)
Its function Is to signal when the gate Is open, partly open or not totally
closed anyway. It turns off only when the gate Is totally closed.
This warning signal is not enabled during the programming procedures.
N.B.: If you overuse the push button panels or the lamps, the control
board logic system may be compromised, resulting into a possible
operation block.
T
ECHNICAL SPECIFICATIONS
- Moisture
- Power supply voltage
- Frequency
- Max. power consumption of the card
- Transient power mains drops
- Max. capacity of the warning light - gate open 3 W (corresponding to 1
- Max. load at blinker output 40W with resistive load
- Available current for photocells and accessories 0,4 A ±15% 24Vac
- Available current for the radio connector 200mA 12Vdc
- All the inputs must be used as clear contacts because the power supply
is generated inside (safe power) the control panel, and it has been laid
down in such a way to guarantee a double or strengthened insulation in
relation to the parts with dangerous power.
- Eventual external circuits connected to the outputs of the control board
or of the expander card must be carried out making sure that a double
or strengthened insulation is used in relation to parts with dangerous
< 95% without condensation
230V~ ±10%
50 Hz
60 mA
100mS
3W lamp or to 5 LEDS
with 2,2 k resistance In
series)
power.
- All inputs are run by a programmed integrated circuit which does a self
check every time it starts operating.
G G
B B

Publicité

Table des Matières
loading

Table des Matières