G G
B B
INSTALLATION SUPER 3600 FAST
C
HECKING BEFORE THE INSTALLATION
!! THE GATE SHALL MOVE FRICTIONLESS !!
N.B.: Gate features must be uniformed with the standards and laws in
force. The door/gate can be automated only if it is in a good condition
and its conditions comply with the EN 12604 norm.
- The door/gate leaf does not have to have a pedestrian opening. In the
opposite case it is necessary to take the appropriate steps, in
accordance with EN 12453 norm (for instance; by preventing the
operation of the motor when the pedestrian opening is opened, by
installing a safety microswitch connected with the control panel).
- Besides the electrical or mechanical limit switches available on the
operators, there must be, on both ends of the installation, a fixed
mechanical stopper which stop the gate in the unlikely event of ill
functioning of limit swithces on the operators. For this reason the fixed
mechanical stopper must be of an adeguate size to withstand the static
and kinetic forces generated by the gate (12) (Fig.2).The guide must
be provided with two mechanical stops at its ends (12) (Fig. 2).
- Gate columns shall have anti-derailment guides on their top (Fig. 3),
to avoid the unintentional gate release.
N.B.: Eliminate those mechanical stops of the kind described by figure
3.
No mechanical stop shall be on top of the gate, since mechanical stops
are not safe enough.
Parts to install meeting the EN 12453 standard
COMMAND TYPE
Skilled persons
(out of public area*)
with manned operation
with visible impulses
(e.g. sensor)
with not visible impulses
(e.g. remote controldevice)
automatic
* a typical example are those shutters which do not have access to any public way.
A: Command button with manned operation (that is, operating as long as activated),
like code ACG2013.
B: Key selector with manned operation, like code ACG1010.
E: Photocells, like code ACG8026 (To apply every 60÷70 cm for all the height of the
column of the gate up to a maximum of 2,5 m - EN 12445 point 7.3.2.1).
E
MERGENCY RELEASE
To be undertaken after disconnecting power supply.
The operator is irreversible and keeps the door closed even without a
lockset.
To open the gate manually, in open the motor cover and turn the knob
"A" anti-clockwise.
To restore electric working you have to turn the lever clockwise (Fig. 4).
In order to carry out the manual operation of the gate leaf the followings
must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for
the operator;
- That the physical effort necessary to move the gate leaf should not be
higher than 225 N, for doors/gates for private dwellings, and, 390N for
doors/gates for commercial and industrial sites ( values indicated in
5.3.5 of the EN 12453 norm).
USE OF THE SHUTTER
Skilled persons
Unrestricted use
(public area)
A
B
non possibile
E
E
E
E
E
E
2"
E
E
E
2"
2
3
4