Ventilation and air-conditioning
↵
In order to preserve the performance of the air-
conditioning unit, clean the heat exchangers after
500 - 600 hours of operation.
Figure 27
Air-conditioning unit
⑰
⑮
Heat exchanger
⑮
Condensate pump
⑰
Condensate tray
Page
Open the bench part.
39
⑮
Clean the heat exchanger.
Vacuum it carefully, paying attention not to
damage the fi ns.
44
U t i l i s a t i o n e t M a i n t e n a n c e |
All manuals and user guides at all-guides.com
⑮
⑯
SERVICING THE VENTILATION SYSTEM
Check all hose connections.
⇒
Remove any kinks in the air hoses. Replace
⇒
defective hoses immediately.
The exhaust air hose must not exceed a
maximum length of 6 m if there is no auxiliary
fan installed.
CHECKING THE CONDENSATE PUMP
The condensate pump ⑯ pumps away the
condensation water at timer-controlled intervals.
Check the function of this pump with each tube
replacement.
Fill some water into the condensate tray ⑰.
⇒
Use a hose and a funnel to do so.
Make sure that the water does not spill over.
Start a tanning session and then wait for 20
⇒
minutes.
The fi lling level of the tray must then be below
⇒
the pump level.