Item:
LVT2-20-CS
LVT4-40-40K
LVT4-50PCS
LVT4-50PCS-EM
LVT4-50PCS-MS
LVT8-70PCS
LVT8-70PCS-MS
LVT-ANGL-MNT
F-LED-CABLE 2PK
INSTALLATION INSTRUCTIONS
Motion Sensor Parameter Setting:
HOLD
DAYLIGHT: 5, 6
www.topaz-usa.com | 800.666.2852 | ©2022 Southwire Company, LLC. All rights reserved.
LVT4-40-50K
LVT4-50PCS-EMS
LVT8-70PCS-EM
LVT-JBOX-MNT
LED LINEAR VAPOR TIGHT
1.
Locate the microwave sensor shown on the previous page.
Remove the from the mount by removing 1 screw and sliding the
sensor out.
2.
On the front of the sensor, you will find switches to set the
parameters for the environment.
•
Switches 1&2 control Sensitivity.
•
Switches 3&4 control Hold Time.
•
Switches 5&6 control the Daylight threshold.
•
Switches 7&8 control Stand-by Light Level.
•
Switches 9&10 control Stand-by Time.
3.
Switches 1 and 2 control the sensitivity. This setting controls the
detection range. Follow the diagram to set the sensitivity needed
for the environment.
4.
Switches 3 and 4 control the Hold Time. This setting controls how
long the fixture will stay illuminated after sensing motion. Follow
the diagram to set the Hold Time.
5.
Switches 5 and 6 control the Daylight threshold. This setting
controls the maximum amount of daylight that will allow the
fixture to illuminate. Follow the diagram to set the Daylight
threshold.
6.
Switches 7 and 8 control the Stand-By Level. This setting controls
the amount of light that will remain after the Hold Time has
expired. Follow the diagram to set the Stand-By Level.
7.
Switches 9 and 10 control the Stand-By Time. This setting controls
the amount of time the fixture will stay on at the Stand-By Level.
Follow the diagram to set the Stand-By Time.
8.
Once the Parameters are set, reinstall the sensor into the fixture.
Close the fixture and turn on power.