Item:
LVT2-20-CS
LVT4-40-40K
LVT4-50PCS
LVT4-50PCS-EM
LVT4-50PCS-MS
LVT8-70PCS
LVT8-70PCS-MS
LVT-ANGL-MNT
F-LED-CABLE 2PK
INSTALLATION INSTRUCTIONS
Model
LVT2-20-CS
LVT4-40-xxK
LVT4-50PCS
LVT4-50PCS-EM
LVT4-50PCS-MS
LVT4-50PCS-EMS
LVT8-70PCS
LVT8-70PCS-EM
LVT8-70PCS-MS
Installation Instructions:
1
2
3
www.topaz-usa.com | 800.666.2852 | ©2022 Southwire Company, LLC. All rights reserved.
LVT4-40-50K
LVT4-50PCS-EMS
LVT8-70PCS-EM
LVT-JBOX-MNT
LED LINEAR VAPOR TIGHT
Input
Voltage
120-277V
120-277V
120-277V
120-277V
Power
Select
CCT
Select
Frequency
Wattage
50/60Hz
20W
50/60Hz
40W
30W
50/60Hz
40W
50W
50W
50/60Hz
60W
70W
1.
Turn off AC power at the circuit breaker before doing any electrical
work.
2.
Open all the latches by pushing them up and unhooking the latch
from the lens. See Figure 1.
3.
Remove the lens to expose the wiring compartment. See Figure 2.
4.
If applicable, choose the desired Wattage and CCT using switches
the on the driver to best suit the application for which the fixture
is installed. See Figure 3.
Rated
Rated
Current 120V
Current 277V
0.183A
0.079A
0.367A
0.159A
0.275A
0.119A
0.367A
0.159A
0.458A
0.199A
0.458A
0.199A
0.555A
0.238A
0.642A
0.278A