CP Softener Series Owner's Manual
Meter Disc and Balance Piston
Step 1
Force the Meter Drive
Pawl against the side of
Level 1. While holding the
Meter Drive Pawl against
the Level 1 side, place
the Meter Disc on top
of the Control Disc with
number facing up. Make
sure the meter disc lies
flat against the control
disc.
Cap
Step 1
Slide the Actuator O-ring
down onto the Actuator.
Step 2
Place the Balance Piston
O-ring in the groove on
the Control Disc.
Step 2
Place the Actuator into
the hole in the D.O. cap.
There is enough friction
that the Actuator will
stay in the D.O. cap.
Step 3
Set the Balance Piston
Spring in the center of
the cup on the Control
Disc.
Step 3
Place the D.O. cap on top
of the Level 1 Assembly,
making sure that the leg
on the Cap goes over the
Level 1 Screen at the 5
o'clock position.
14
Step 4
Place the Balance Piston
on top of the Balance
Piston Spring.
Step 4
Secure the D.O. cap with
8 cap screws.