Télécharger Imprimer la page

Wolf 814426 Mode D'emploi page 2

Publicité

Les langues disponibles

Les langues disponibles

DUAL BLOWER INSTALLATION
For blower models 814422 & 814423
1. Mount blowers to ADAPTER PLATE with (8) 10-24 NUTS
(provided).
(4) THREADED
STUDS
HOOD
TOP
PLATE
2. Lower the (4) THREADED STUDS on the adapter plate /
blower assembly down through the holes in the HOOD TOP
PLATE. Use (4) 1/4-20 HEX NUTS to secure in place.
3. Plug blower POWER CORD into the receptacle inside the
hood. Route wires away from the blower's moving parts. Bundle
wires with wire tie (provided).
ADAPTER PLATE
(8) 10-24 NUTS
POWER
CORD
(4) 1/4-20
HEX NUTS
SINGLE BLOWER INSTALLATION
For blower models 814419, 814420 & 814421
MOUNTING PLATE
CENTER
PIECE
(4) 10-24 NUTS
1. Mount blower to MOUNTING PLATE (provided with blower)
with (4) 10-24 NUTS (provided).
2. Remove CENTER PIECE of ADAPTER PLATE.
3. Mount blower / mounting plate assembly to ADAPTER PLATE
using (4) 10-24 NUTS (provided).
(4) THREADED
STUDS
HOOD
TOP
PLATE
(4) 1/4-20
HEX NUTS
4. Lower the (4) THREADED STUDS on the adapter plate /
blower assembly down through the holes in the HOOD TOP
PLATE. Use (4) 1/4-20 HEX NUTS to secure in place.
5. Plug blower POWER CORD into receptacle inside of hood.
Route wires away from the blower's moving parts. Bundle
wires with wire tie (provided).
MODEL • 814426
ADAPTER PLATE
(4) 10-24 NUTS
POWER
CORD
99044555A
815069A

Publicité