Télécharger Imprimer la page

Wonder EURODAINU 1991 Mode D'emploi page 6

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
INFLATOR GAUGE
GENERAL INFORMATION
Wonder inflator gauge is designed, manufactured and certified in
Italy using advanced technology. It complies with the European
directive 86/217/EEC
and the regulation UNI EN 12645:2014.
2
Wonder carefully checks the origin and quality of all materials and
components used in production to offer its customers high quality
products that are guaranteed and also to reduce the impact on the
environment to a minimum. Our quality systems are ISO 9001 and
ISO 14001 certified. You are invited to observe the local laws and
regulations regarding this product to prevent accident or injury and
also control the general safety regulations for the use of this product.
Wonder denies any liability for any errors in measurement or
damage that could be caused by the following: incorrect or
inappropriate use of this product or any of its single components;
not following the instructions provided in this manual; use by
unqualified individuals; unauthorized modifications or alterations
to this product. This device is designed for intended use only,
i.e. measurement, inflation and regulation of internal pressure of
motor vehicles tyres. Any other use is considered inappropriate.
Model with Pe (bar) scale
2
GENERAL WARNINGS
• During inflation, maintain a safe distance to avoid injury due to accidental
bursting of the tyre.
• With the gauge connected to the tyre, operate the handle and discharge
valve briefly 2/3 times to prepare the tool, and then proceed with inflation/
deflation.
• Never block the handle in the inflating position as this would result in a
continuous flow of air into the tyre that would produce a high risk of the
tyre exploding.
• Check that the pressure from the compressor is higher than the pressure
recommended by the tyre manufacturer.
• Ensure that the air or nitrogen from the compressor passes through a
separator filter to prevent liquids (e.g. hydrocarbons) or other impurities
from entering into the inflator gauge causing oxidation of the internal
components and damaging the system of measurement.
• Constant or prolonged use when the instrument is under pressure using
pressured air or nitrogen can, in the course of time, alter the variables of
the measurement system producing an incorrect reading on the dial. It is
therefore recommended that the instrument is not left in use for long periods.
• Wonder inflator gauge is tested to resist levels of pressure up to 15 bar/ 218
psi/1,500 kPa only for short periods of time. In order to always guarantee
precise measurements and retain the calibration for the maximum amount
of time, it is recommended that the limit indicated above is respected.
• To obtain best results, the operating temperature should be between 15�
and 25�C.
• Avoid knocks to the inflator gauge - do not disassemble.
All manuals and user guides at all-guides.com
WONDER SPA
10
INFLATOR GAUGE
• Do not expose to bad weather conditions or direct sunlight and avoid
sudden changes in temperature.
• Do not submerge in water or detergents. Clean the instrument using a damp cloth.
• Do not use for inflation or checking pressure of tyres containing water
ballast or anti-puncture products.
• Avoid contact with solvents or hydrocarbons.
• Periodically check that the filter near the inlet of air from the compressor is
in correct working order.
• Keep the product, its accessories and any packing materials out of reach
of children.
• The disposal of this product must conform to the local regulations in force
to respect the environment and correct waste disposal.
• Do not attempt to inflate the tyre if the gauge is not connected to a compressor
or other source of air or nitrogen as this will cause the tyre to deflate.
• It is recommended to use original Wonder accessories.
Only qualified staff authorised by Wonder can carry out repairs.
Wonder does not repair any instruments over 5 years after their date of
production and does not accept, either for inspection or repairs, instruments
with missing pieces or instruments on which attempts have been made to
take them apart or modify them.
TECHNICAL SPECIFICATIONS
: 0.7 - 12 bar | 10 - 174 psi | 70 - 1,200 kPa
Measurement range
3
Instrument resolution: 0.1 bar | 1.45 psi | 10 kPa
Operating temperature: -10�C - +40�C
Performance according to Standard UNI EN 12645
/h at 10 bar | 145 psi | 1,000 kPa
Maximum airflow: 66 m
3
Maximum air source pressure: 15 bar | 218 psi | 1,500 kPa
TECHNICAL SPECIFICATIONS
Measurement range
: 0.7 - 11 bar
3
Instrument resolution: 0.1 bar
Operating temperature: -25�C - +55�C
Model approved according to Directive 86/217/EEC and
Standard UNIEN 12645:2014
/h at 10 bar | 145 psi | 1,000 kPa
Maximum airflow: 66 m
3
Maximum air source pressure: 15 bar | 218 psi | 1,500 kPa
The black square placed on the dial before the beginning of the scale indicates the
3
resting position of the pointer. It has illustrative purposes only and can not be used
for calibration. Changes in position of the pointer with respect to this reference do not
imply an incorrect calibration.
WONDER SPA
2 0 1 5
11

Publicité

loading

Produits Connexes pour Wonder EURODAINU 1991