WIRING DIAGRAM
This wiring diagram is for all models.
Volt: 240 V
Frequency: 60 Hz
MOTOR
OPERATING INSTRUCTIONS
A
OVERLOAD
PROTECTION
PRESS TO
RESET
B
C
Parts of the Control Box
A
LED Display
B
Overload Protection
C
Speed Switch
D
Direction Rocker Switch
E
Power Switch
HVLS BLDC Fan
Fire
POWER 240V/60Hz
G2
U
V
W
4x16AWG WIRE
OFF
REV
FWD
ON
SPEED
D
E
_
+
G1
G1
L2
L2
L1
L1
G2
U
V
W
Before turning on or restarting the fan, you
must confirm that all the fan blades are
completely stationary. Never turn on the fan
while the fan blades are still moving, otherwise
the motor may be damaged.
1. Press the Power Switch on, the LED display will light up and work
state show [STAND BY].
2. Press the Direction Rocker Switch to [FWD],
and turn on the Speed Switch slowly. The LED
display will show the current and speed. The fan
blade rotates counterclockwise and the air will
blow down.
A downward air flow creates a cooling effect.
This allows you to set your air conditioner on a
higher temperature setting without affecting your
comfort.
Press the Direction Rocker Switch to [REV],
and turn on the Speed Switch slowly.The LED
display will show the current and speed. The
fan blade rotates clockwise and the air will blow
up.
An upward airflow moves warm air off the ceiling
area. This allows you to set your heating unit on
a lower setting without affecting your comfort.
Note: When the fan blades start rotating, a little sound and vibration
is normal. But if the motor makes a loud noise, please press
the Power Switch off immediately. Wait until the fan blades are
completely stationary, and check out each part of the fan's
installation, make sure that the fan is ok. Then repeat the
steps above.
3. To shutdown the fan , please turn off the Speed Switch slowly.
Wait until the fan blades are completely stop, and then press the
Power Switch off.
10
User's Manual
control
Fire alarm
switch
Fire PCB
10V GND X3
PCBA
FWD
REV