INSTALLATION
Positioning the heater
•
The heater must be positioned in such a way that there is a safe
distance between flammable materials and the external surfaces
of the heater. See Table 3.
In installing the heater, it must be prevented that people could
•
have physical contact with the heater or that other dangerous
situations could emerge during the heating process.
CLIFF Mini holds approximately 132 lb (60 kg) of stones and CLIFF
•
holds approximately 330 lb (150 kg).
The input of the power cable is located on the bottom cover of
•
the heater.
Connecting the heater to the power supply
•
A method to disconnect all poles from the mains (a circuit
breaker) must be installed on the power circuit before the sauna
controller.
Only a certified electrician is allowed to connect the heater to the
•
•
power supply.
The power cable of the heater must meet the requirements of UL
•
62 in US and CSA 49 in Canada.
It is recommended to connect the unit to the mains without an
•
earth-leakage circuit breaker.
The maximum current intensity in the cross-sectional area of the
•
cable and circuit breaker are listed in Table 1 and Table 2.
The cable must be secured to the clamp on the cover screw.
•
NB!
It is forbidden to use a non-heat-resistant cable with PVC isolation
as the power cable. The joint box must be waterproof and it must be
located up to 20 in (50 cm) from the floor.