THINGS TO CHECK BEFORE INSTALLATION
Does the output (kW) match the volume (ft³/m³) of the sauna
•
room? See Table 1-2.
In case there are any uninsulated brick, tile or glass walls in the
•
sauna room, an additional volume of 53 ft³ (1.5 m³) should be
added to the sauna room for each 11 ft
•
The suitable output of the heater will be determined based on
Table 1-2.
The producer's warranty guarantee is invalid if the heater and
•
sauna room have been dimensioned incorrectly!
Minimal safe distances between the sauna room's ceiling and
•
walls in view of installing the electric heater are listed in Table 3.